User`s manual
Table Of Contents
- Mediant 2000 & TP-1610 & TP-260/UNI SIP User’s Manual Version 5.0
- Table of Contents
- List of Figures
- List of Tables
- Notices
- 1. Overview
- 2. Physical Description
- 3. Installation
- 4. Getting Started
- 5. Web Management
- Computer Requirements
- Protection and Security Mechanisms
- Accessing the Embedded Web Server
- Getting Acquainted with the Web Interface
- Protocol Management
- Advanced Configuration
- Status & Diagnostic
- Software Update Menu
- Maintenance
- Logging Off the Embedded Web Server
- 6. Gateway's ini File Configuration
- Secured ini File
- Modifying an ini File
- The ini File Content
- The ini File Structure
- The ini File Example
- Networking Parameters
- System Parameters
- Web and Telnet Parameters
- Security Parameters
- RADIUS Parameters
- SNMP Parameters
- SIP Configuration Parameters
- Voice Mail Parameters
- ISDN and CAS Interworking-Related Parameters
- Number Manipulation and Routing Parameters
- E1/T1 Configuration Parameters
- Channel Parameters
- Configuration Files Parameters
- 7. Using BootP / DHCP
- 8. Telephony Capabilities
- Working with Supplementary Services
- Configuring the DTMF Transport Types
- Fax & Modem Transport Modes
- Event Notification using X-Detect Header
- ThroughPacket™
- Dynamic Jitter Buffer Operation
- Configuring the Gateway’s Alternative Routing (based on Conn
- Call Detail Report
- Supported RADIUS Attributes
- Trunk to Trunk Routing Example
- Proxy or Registrar Registration Example
- SIP Call Flow Example
- SIP Authentication Example
- 9. Networking Capabilities
- 10. Advanced PSTN Configuration
- 11. Advanced System Capabilities
- 12. Special Applications
- 13. Security
- 14. Diagnostics
- 15. SNMP-Based Management
- SNMP Standards and Objects
- Carrier Grade Alarm System
- Cold Start Trap
- Third-Party Performance Monitoring Measurements
- TrunkPack-VoP Series Supported MIBs
- Traps
- SNMP Interface Details
- SNMP Manager Backward Compatibility
- Dual Module Interface
- SNMP NAT Traversal
- SNMP Administrative State Control
- AudioCodes’ Element Management System
- 16. Configuration Files
- Appendix A. Selected Technical Specifications
- Appendix B. Supplied SIP Software Kit
- Appendix C. SIP Compliance Tables
- Appendix D. The BootP/TFTP Configuration Utility
- Appendix E. RTP/RTCP Payload Types and Port Allocation
- Appendix F. RTP Control Protocol Extended Reports (RTCP-XR)
- Appendix G. Accessory Programs and Tools
- Appendix H. Release Reason Mapping
- Appendix I. SNMP Traps
- Appendix J. Installation and Configuration of Apache HTTP Server
- Appendix K. Regulatory Information

SIP User's Manual 3. Installation
Version 5.0 37 October 2006
Figure 3-2: Mediant 2000 Front View with 19-inch Rack Mount Brackets
Rack Mount Safety Instructions (UL)
When installing the chassis in a rack, be sure to implement the following
Safety instructions recommended by Underwriters Laboratories:
• Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
• Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation on the equipment is not
compromised.
• Mechanical Loading - Mounting of the equipment in the rack should be such
that a hazardous condition is not achieved due to uneven mechanical loading.
• Circuit Overloading - Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when
addressing this concern.
• Reliable Earthing - Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g., use of power strips.)
¾ To attach the device to a 19-inch rack, take these 2 steps:
1. Position the device in your 19-inch rack and align the left-hand and right-hand bracket
holes to holes (of your choosing) in the vertical tracks of the 19-inch rack.
2. Use standard 19-inch rack bolts (not provided) to fasten the device to the frame of the
rack.
AudioCodes recommends using two additional (not supplied) rear mounting brackets to
provide added support.
Note: Users assembling the rear brackets by themselves should note the
following:
• The distance between the screws on each bracket is 26.5 mm.
• To attach the brackets, use 4-40 screws with a maximal box penetration
length of 3.5 mm.