User`s manual

Table Of Contents
SIP User's Manual 12. Special Applications
Version 5.0 275 October 2006
Table 12-4: SS7 Signaling Link (continues on pages 274 to 275)
ini File Parameter Name Description
SS7_LINK_LAYER2_VARIANT
[Variant]
Determines the variant (layer 2) of signaling link (TDM).
0 = NET_VARIANT_OTHER
1 = NET_VARIANT_ITU (default)
2 = NET_VARIANT_ANSI
3 = NET_VARIANT_CHINA
SS7_LINK_MTP2_ATTRIBUTES
[MTP2 Attributes Index]
Determines the MTP2 attributes of signaling link (TDM).
The valid range is 0 to MAX_C7_MTP2_PARAMS_INDEX. The
default value is 3.
SS7_CONGESTION_LOW_MARK
[Congestion Low Watermark]
Determines the link congestion low mark of signaling link (TDM).
The valid range is 0 to 255. The default value is 5.
SS7_CONGESTION_HIGH_MARK
[Congestion High Watermark]
Determines the link congestion high mark of signaling link (TDM).
The valid range is 0 to 255. The default value is 20.
SS7_LINK_M2UA_IF_ID
[Interface ID]
Determines the interface ID (M2UA) of signaling link.
The valid range is 0 to 0xFFFFFFFF. The default value is 0.
SS7_LINK_GROUP_ID
[Group ID]
Determines the group ID (M3UA) of signaling link.
The valid range is 0 to 0xFFFF. The default value is 0.
SS7_LINK_TNL_MGC_LINK_NUMBER
Determines the MTP2 Tunneling: MGC link number (MTP2 \other
side\ of signaling link.
The valid range is 0 to 7. The default value is 0.
SS7_LINK_TNL_ALIGNMENT_MODE
Determines the MTP2 Tunneling: Alignment mode of signaling links
in tunnel.
0 = M3B_ALIGNMENT_NORMAL
1 = M3B_ALIGNMENT_EMERGENCY (default)
SS7_LINK_TNL_CONGESTION_MOD
E
Determines the MTP2 Tunneling: Congestion mode of signaling links
in tunnel.
0 = M3B_CONGESTION_ACCEPT (default)
1 = M3B_CONGESTION_DISCARD
SS7_LINK_TNL_WAIT_START_COMP
LETE_TIMER
Determines the MTP2 Tunneling Timer: wait start complete.
The valid range is 500 to 0xFFFFFFFF. The default value is 30000.
SS7_LINK_TNL_OOS_START_DELAY
_TIMER
Determines the MTP2 Tunneling Timer: OOS start delay.
The valid range is 500 to 0xFFFFFFFF. The default value is 5000.
SS7_LINK_TNL_WAIT_OTHER_SIDE_
INSV_TIMER
Determines the MTP2 Tunneling Timer: wait other side inservice.
The valid range is 500 to 0xFFFFFFFF. The default value is 30000.
SS7_LINKSET_SN_INDEX
[SN Number]
Determines the first index field for line.
The valid range is 0 to 1. The default value is 0.
SS7_LINKSET_LINKSET_INDEX
[Link-set Number]
Determines the second index field for line.
The valid range is 0 to 7. The default value is 0.
SS7_LINKSET_ROWSTATUS
Determines the RowStatusField for line.
The valid range is acPARAMSET_ROWSTATUS_DOESNOTEXIST
to acPARAMSET_ROWSTATUS_DESTROY. The default value is
acPARAMSET_ROWSTATUS_DOESNOTEXIST.
SS7_LINKSET_ACTION
Determines the management field for actions.
0 = acSS7LINKSET_PS_ACTION_NONE (default)
1 = acSS7LINKSET_PS_ACTION_OFFLINE
2 = acSS7LINKSET_PS_ACTION_INSERVICE
3 = acSS7LINKSET_PS_ACTION_ACTIVATE
4 = acSS7LINKSET_PS_ACTION_DEACTIVATE
SS7_SN_ACTION_RESULT
Determines the management field for actions result.
The valid range is acPARAMSET_ACTION_RESULT_SUCCEEDED
to acPARAMSET_ACTION_RESULT_FAILED. The default value is
acPARAMSET_ACTION_RESULT_SUCCEEDED.