User`s manual

Table Of Contents
Mediant 2000 & TP-1610 & TP-260
SIP User's Manual 272 Document #: LTRT-68805
Table 12-1: SS7 Parameters (continues on pages 271 to 272)
ini File Parameter Name Description
SS7_MTP2_Param_Timer_T5
[T5]
Defines the SS7 MTP2 Sending SIB timer.
The valid range is 0 to 2400.
The default value is 120.
SS7_MTP2_Param_Timer_T6
[T6]
Defines the SS7 MTP2 Remote Congestion timer (in msec).
The valid range is 0 to 10000.
The default value is 6000.
SS7_MTP2_Param_Timer_T7
[T7]
Defines the SS7 MTP2 excessive delay of the ack timer (in msec).
The valid range is 0 to 5000.
The default value is 2000.
12.2.4 SS7 Parameter Tables
For detailed information on parameter tables, refer to Section 11.5 on page 253.
12.2.4.1 SIGTRAN Interface Groups
Table 12-2: SIGTRAN Interface Groups (continues on pages 272 to 273)
ini File Parameter Name Description
SS7_SIG_IF_GR_INDEX
[Group Number]
Indicates the SS7 interface group index for a line.
The valid range is 0 to 15.
SS7_IF_GR_ID
[Group ID]
Determines the SS7 SIGTRAN interface group index, for a line.
The valid range is 0 to 0xFFFF.
The default value is 0xFFFE.
SS7_SIG_SG_MGC
[UAL Group Number]
Determines the SS7 SIGTRAN interface group Signaling Gateway
(SG) and Media Gateway Controller (MGC) option.
The valid range is 77(MGC), 83(SG).
The default value is 83.
SS7_SIG_LAYER
[Group Layer]
Determines the SIGTRAN group layer (IUA/M2UA/M3UA).
Choose either:
0 = no_layer (default)
1 = iua
2 = m2ua
3 = m3ua
4 = m2tunnel
5 = V5ua
SS7_SIG_TRAF_MODE
[Group Traffic Mode]
Determines the SS7 SIGTRAN interface group traffic mode.
The valid range is 1 to 3.
The default value is 1.
SS7_SIG_T_REC
[Tr - Group Recovery Timer]
Determines the SIGTRAN group T recovery.
The valid range is 0 to 10000000.
The default value is 2000.
SS7_SIG_T_ACK
[Ta - Group Acknowledge Timer]
Determines the SIGTRAN group T Ack (in msec).
The valid range is 0 to 10000000.
The default value is 2000.
SS7_SIG_T_HB
[Th - Group Heartbeat Timer]
Determines the SIGTRAN group T Hb (in msec).
The valid range is 0 to 10000000.
The default value is 2000.
SS7_SIG_MIN_ASP
[Group Minimal ASP Number]
Determines the SIGTRAN group minimal Application Server Process
(ASP) number (minimum = 1).
The valid range is 1 to 10
The default value is 1.