Specifications

Spectralink 84-Series with AudioCodes Gateway and Avaya Communication Manager: Interoperability Guide
1725-86914-000_C.docx
September 2013 111
4. Configure the AudioCodes Mediant Gateway
On the Mediant Gateway side there are two possibilities; the first is that we have a single T1
module with two PRI interfaces in it, and the second is that we have two separate T1 modules
each with a single PRI interface. Trunk Group settings need to be changed depending on which
system you are using.
a. Change the Trunk Group settings
Two PRI interfaces in one T1 module
1 Select the Configuration tab and navigate to VOIP > GW and IP to IP > Trunk Group >
Trunk Group.
2 Change these settings:
Module
Select the module for the second PRI (The same module as the first PRI)
From Trunk
2
To Trunk
2
Channels
1-23
Phone Number
100024 (Begin with the next available channel number)
Trunk Group ID
1
Tel Profile ID
0
3 Press Submit and Burn.