User`s manual

Version 5.4 99 May 2008
SIP User's Manual 3. Web-Based Management
ini File Field Name
Web Parameter Name
Valid Range and Description
[19] E1 KOR ISDN = Korean operator
[20] T1 HKT ISDN = Hong Kong - HKT over T1
[21] E1 QSIG
[23] T1 QSIG
[31] E1 FRENCH VN3 ISDN
[35] T1 DMS100 Meridian ISDN
[40] E1 NI2 ISDN
[41] E1 CAS R15
[50] BRI EURO ISDN
[51] BRI NI2 ISDN
[52] BRI DMS100 ISDN
[53] BRI 5ESS 10 ISDN
[54] BRI QSIG
[56] BRI NTT = BRI ISDN Japan (Nippon Telegraph)
Note: The device simultaneously supports different variants of CAS and
PRI protocols on different E1/T1 spans (no more than four simultaneous
PRI variants).
Clock Master
[ClockMaster]
Determines the Tx clock source of the E1/T1 line.
[0] Recovered = Generate the clock according to the Rx of the E1/T1
line (default).
[1] Generated = Generate the clock according to the internal TDM
bus.
Notes:
The source of the internal TDM bus clock is determined by the
parameter TDMBusClockSource.
For detailed information on configuring the device's clock settings,
refer to ''Clock Settings'' on page 459.
Auto Clock Trunk Priority
[AutoClockTrunkPriority]
Defines the trunk priority for auto-clock fallback (per trunk parameter).
0 to 99 = priority (0 is the highest = default).
100 = the SW never performs a fallback to that trunk (usually used to
mark untrusted source of clock).
Note: Fallback is enabled when the TDMBusPSTNAutoClockEnable
parameter is set to 1.
Line Code
[LineCode]
Use to select B8ZS or AMI for T1 spans, and HDB3 or AMI for E1 spans.
[0] B8ZS = use B8ZS line code (for T1 trunks only) default.
[1] AMI = use AMI line code.
[2] HDB3 = use HDB3 line code (for E1 trunks only).
Note: This parameter is not configurable for BRI interfaces; the device
automatically uses the Modified Alternate Mark Invert (MAMI) line code.