User`s manual

SIP User's Manual 94 Document #: LTRT-83303
Mediant 1000 & Mediant 600
Table 3-19: Media Settings Parameters
Parameter Description
Max Echo Canceller Length
[MaxEchoCancellerLength]
Maximum Echo Canceler Length (in msec):
[0] Default = based on various internal device settings to attain
maximum channel capacity (default)
[11] = 64 msec
[22] = 128 msec
Notes:
Mediant 1000 with analog / BRI module can use a max. echo
canceller length of 64 msec.
Mediant 1000 with PRI can use a max. echo canceller length
of 128 msec.
When set to 128 msec, the number of available Mediant 1000
channels is reduced by a factor of 5/6.
When the Mediant 1000 houses an MPM module (in Slot #6)
no channel reduction occurs.
Reset the device after modifying this parameter.
It isn't necessary to configure the parameter
EchoCancellerLength as it automatically acquires its value
from this parameter.
Enable Continuity Tones N/A.
3.4.2.6 Configuring the Hook-Flash Settings
The 'Hook-Flash Settings' page allows you to configure hook-flash parameters.
Note: The 'Hook-Flash Settings' page is applicable only to Mediant 1000.
¾ To configure the Hook-Flash parameters, take these 4 steps:
1. Open the 'Hook-Flash Settings' page (Configuration tab > Media Settings menu >
Hook-Flash Settings page item).
Figure 3-53: Hook-Flash Settings Screen
2. Configure the hook-flash parameters according to the table below.
3. Click the Submit button to save your changes.
4. To save the changes to flash memory, refer to ''Saving Configuration'' on page 265.