User`s manual
Version 5.4 419 May 2008
SIP User's Manual 7. IP Telephony Capabilities
7.10 Supported RADIUS Attributes
Use the following table for explanations on the RADIUS attributes contained in the
communication packets transmitted between the device and a RADIUS Server.
Table 7-3: Supported RADIUS Attributes
Attribute
Number
Attribute
Name
VSA
No.
Purpose
Value
Format
Example AAA
1
Request Attributes
1 User-Name
Account number or calling
party number or blank
String up
to 15
digits long
5421385747
Start Acc
Stop Acc
4
NAS-IP-
Address
IP address of the requesting
device
Numeric
192.168.14.4
3
Start Acc
Stop Acc
6 Service-Type Type of service requested Numeric 1: login
Start Acc
Stop Acc
26
H323-
Incoming-
Conf-Id
1 SIP call identifier
Up to 32
octets
Start Acc
Stop Acc
26
H323-Remote-
Address
23
IP address of the remote
gateway
Numeric
Stop Acc
26 H323-Conf-ID 24 H.323/SIP call identifier
Up to 32
octets
Start Acc
Stop Acc
26
H323-Setup-
Time
25 Setup time in NTP format 1 String
Start Acc
Stop Acc
26
H323-Call-
Origin
26
The call’s originator:
Answering (IP) or Originator
(PSTN)
String
Answer,
Originate etc
Start Acc
Stop Acc
26
H323-Call-
Type
27
Protocol type or family used
on this leg of the call
String VoIP
Start Acc
Stop Acc
26
H323-Connect-
Time
28 Connect time in NTP format String
Stop Acc
26
H323-
Disconnect-
Time
29
Disconnect time in NTP
format
String
Stop Acc
26
H323-
Disconnect-
Cause
30
Q.931 disconnect cause
code
Numeric
Stop Acc
26 H323-Gw-ID 33 Name of the gateway String SIPIDString
Start Acc
Stop Acc
26 SIP-Call-ID 34 SIP Call ID String
abcde@ac.c
om
Start Acc
Stop Acc
26
Call-
Terminator
35
The call's terminator: PSTN-
terminated call (Yes); IP-
terminated call (No).
String Yes, No Stop Acc
30
Called-Station-
String 8004567145 Start Acc