User`s manual
SIP User's Manual 354 Document #: LTRT-83303
Mediant 1000 & Mediant 600
ini File Parameter Description
SendIEonTG
For a description of this parameter, refer to ''Configuring the Digital
Gateway Parameters'' on page 235.
ISDNDMSTimerT310
Overrides the T310 timer for the DMS-100 ISDN variant.
T310 defines the timeout between the reception of a PROCEEDING
message and the reception of an ALERTING / CONNECT message.
The valid range is 10 to 30. The default value is 10 (seconds).
Note: Applicable only to Nortel DMS and Nortel MERIDIAN PRI variants
(ProtocolType = 14 and 35).
ISDNJapanNTTTimerT3J
A
T3_JA timer (in seconds). This parameter overrides the internal PSTN
T301 timeout on the Users Side (TE side).
If an outgoing call from the device to ISDN is not answered during this
timeout, the call is released.
The valid range is 10 to 240. The default value is 50.
Applicable only to Japan NTT PRI variant (ProtocolType = 16).
Note: This timer is also affected by the parameter PSTNAlertTimeout.
BriLayer2Mode
For a description of this parameter, refer to ''Configuring the Trunk
Settings'' on page 96.
EnablePatternDetector
For a description of this parameter, refer to "Configuring the Digital
Gateway Parameters" on page 235.
PDPattern
Defines the patterns that can be detected by the Pattern Detector.
The valid range is 0 to 0xFF.
PDThreshold
Defines the number of consecutive patterns to trigger the pattern detection
event.
The valid range is 0 to 31. The default is 5.
Enable911LocationIdIP2
Tel
Enables interworking of Emergency Location Identification from SIP to
PRI.
[0] = Disabled (default)
[1] = Enabled
When enabled, the From header received in the SIP INVITE is translated
into the following ISDN Information Elements (IE):
Emergency Call Control IE.
Generic Information IE to carry the Location Identification Number
information.
Generic Information IE to carry the Calling Geodetic Location
information.
Note: This capability is supported only for the NI-2 ISDN variant.
EarlyAnswerTimeout
Defines the time (in seconds) that the device waits for a CONNECT
message from the called party (Tel side) after sending a SETUP
message. If the timer expires, the call is answered by sending a 200 OK
message (IP side).
The valid range is 0 to 600. The default value is 0 (i.e., disabled).