ini File Parameter Description
FarEndDisconnectSilenc
eThreshold
Threshold of the packet count (in percentages) below which is
considered silence by the device.
The valid range is 1 to 100%. The default is 8%.
Note: Applicable only if silence is detected according to packet count
(FarEndDisconnectSilenceMethod = 1).
Automatic Update Parameters
CmpFileURL
Specifies the name of the cmp file and the location of the server (IP
address or FQDN) from which the device loads a new cmp file and
updates itself. The cmp file can be loaded using HTTP, HTTPS, FTP,
FTPS, or NFS.
For example: http://192.168.0.1/filename
Notes:
When this parameter is set in the ini file, the device always loads the
cmp file after it is reset.
The cmp file is validated before it's burned to flash. The checksum of
the cmp file is also compared to the previously-burnt checksum to
avoid unnecessary resets.
The maximum length of the URL address is 255 characters.
IniFileURL
Specifies the name of the ini file and the location of the server (IP
address or FQDN) from which the device loads the ini file. The ini file can
be loaded using: HTTP, HTTPS, FTP, FTPS or NFS.
For example:
http://192.168.0.1/filename
http://192.8.77.13/config<MAC>
https://<username>:<password>@<IP address>/<file name>
Notes:
When using HTTP or HTTPS, the date and time of the ini file are
validated. Only more recently-dated ini files are loaded.
The optional string '<MAC>' is replaced with the device's MAC
address. Therefore, the device requests an ini file name that contains
its MAC address. This option enables loading different configurations
for specific devices.
The maximum length of the URL address is 99 characters.
PrtFileURL
Specifies the name of the Prerecorded Tones file and the location of the
server (IP address or FQDN) from which it is loaded.
For example: http://server_name/file, https://server_name/file.
Note: The maximum length of the URL address is 99 characters.
CptFileURL
Specifies the name of the CPT file and the location of the server (IP
address or FQDN) from which it is loaded.
For example: http://server_name/file, https://server_name/file.
Note: The maximum length of the URL address is 99 characters.
FXSCoeffFileURL
Specifies the name of the FXS coefficients file and the location of the
server (IP address or FQDN) from where it is loaded.
For example: http://server_name/file, https://server_name/file.
The maximum length of the URL address is 99 characters.
Note: This parameter is applicable only to Mediant 1000.