User`s manual
SIP User's Manual 178 Document #: LTRT-83303
Mediant 1000 & Mediant 600
Parameter Description
Enable Call Forward
[EnableForward]
Determines whether Call Forward is enabled.
[0] Disable = Disable the Call Forward service.
[1] Enable = Enable Call Forward service (using REFER) (default).
For Mediant 1000 FXS interfaces, the 'Call Forward' table (refer to "Call
Forward" on page 222) must be defined to use the Call Forward service.
Note: To use this service, the devices at both ends must support this
option.
Enable Call Waiting
[EnableCallWaiting]
Determines whether Call Waiting is enabled.
[0] Disable = Disable the Call Waiting service.
[1] Enable = Enable the Call Waiting service (default).
If enabled, when an FXS interface (only Mediant 1000) receives a call on a
busy endpoint, it responds with a 182 response (and not with a 486 busy).
The device plays a call waiting indication signal. When hook-flash is
detected, the device switches to the waiting call. The device that initiated
the waiting call plays a Call Waiting Ringback tone to the calling party after
a 182 response is received.
Notes:
The device's Call Progress Tones file must include a Call Waiting
Ringback tone (caller side) and a Call Waiting tone (called side, FXS
only).
The EnableHold parameter must be enabled on both the calling and the
called side.
For Mediant 1000 analog: You can use the ini file table parameter
CallWaitingPerPort to enable Call Waiting per port (refer to "Call
Waiting" on page 225).
For information on the Call Waiting feature, refer to ''Call Waiting'' on
page 440.
For information on the Call Progress Tones file, refer to Configuring the
Call Progress Tones File.
Number of Call Waiting
Indications
[NumberOfWaitingIndic
ations]
Number of Call Waiting indications that are played to the called telephone
that is connected to the device (FXS only) for Call Waiting.
The valid range is 1 to 100 indications. The default value is 2.
Note: This parameter is applicable only to Mediant 1000.
Time Between Call
Waiting Indications
[TimeBetweenWaitingIn
dications]
Time (in seconds) between consecutive call waiting indications (FXS only)
for call waiting.
The valid range is 1 to 100. The default value is 10.
Note: This parameter is applicable only to Mediant 1000.
Time Before Waiting
Indications
[TimeBeforeWaitingIndi
cation]
Defines the interval (in seconds) before a call waiting indication is played to
the port that is currently in a call (FXS only).
The valid range is 0 to 100. The default time is 0 seconds.
Note: This parameter is applicable only to Mediant 1000.
Waiting Beep Duration
[WaitingBeepDuration]
Duration (in msec) of call waiting indications that are played to the port that
is receiving the call (FXS only).
The valid range is 100 to 65535. The default value is 300.
Note: This parameter is applicable only to Mediant 1000.