Installation manual

Installation Manual 34 Document #: LTRT-85605
Mediant 600
3.1.4 Assigning an IP Address using the CLI
You can assign an IP address to the device, using command-line interface (CLI).
¾ To assign an IP address via the CLI:
1. Connect the device's RS-232 port to either COM1 or COM2 communication port on
your PC (refer to ‘Connecting the RS-232 Port to a PC’ on page 25).
2. Use a serial communication software (e.g., HyperTerminal
TM
) to establish a serial
communication link with the device, using the following communications port settings:
Baud Rate: 115,200 bps
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
The CLI prompt appears.
3. At the prompt, type conf, and then press <Enter>; the configuration folder is
accessed.
4. To view the current network parameters, at the prompt, type GCP IP, and then press
<Enter>; the current network settings are displayed.
5. Change the network settings by typing the following:
SCP IP [ip_address] [subnet_mask] [default_gateway]
For example,
SCP IP 10.13.77.7 255.255.0.0 10.13.0.1
The new settings take effect on-the-fly and connectivity to the device is active at the
new IP address.
Note: This command requires you to enter all three network parameters (each
separated by a space).
6. To save the configuration, at the prompt, type SAR, and then press <Enter>; the device
restarts with the new network settings.