Specifications
310HD, 320HD and 420HD IP Phones
Administrator's Manual 34 Document #: LTRT-09910
Via Configuration File:
Table 5-1: TR-069 Management Parameters
Parameter Description
Note: To add a value to these parameters, enter management/ followed by the parameter name,
equal sign and then the value (e.g. management/tr069/enabled=0).
Activate
[management/tr069/enabled]
Enables TR-069.
[0] Disable (default)
[1] Enable
Note: This feature can be enabled only if the valid
key is provided in the feature_key field.
Activation Key
[management/tr069/activation_key]
Activation key to enable TR-069 management.
ACS URL
[management/tr069/acs_url]
URL for connecting the device to the ACS.
Note: This parameter must be in the form of a valid
HTTP or HTTPS URL.
User
[management/tr069/user_name]
Username used to authenticate the device when
making a connection to the ACS.
Password
[management/tr069/password]
Password used to authenticate the device when
making a connection to the ACS.
Request Connection User
[management/tr069/connection_request/
user_name]
Username to authenticate an ACS making a
Connection Request to the device.
Request Connection Password
[management/tr069/connection_request/
password]
Password to authenticate an ACS making a
Connection Request to the device.
Periodic Inform
[management/tr069/inform/enabled]
Determines whether or not the device must
periodically send device information to the ACS
using the Inform method call.
[0] Disable
[1] Enable (default)
Periodic Inform Interval
[management/tr069/inform/interval]
The duration (in seconds) of the interval for which
the device must attempt to connect with the ACS
and call the Inform method if TR-069 is enabled
(management/tr069/inform/enabled).
The valid range is 0 to 86400. The default is 3600.