Owner`s manual

page 9 – 4
RD-12 / March 99
S U P E R P H O N E I NP U T
Internal Programming Options
Main Printed Circuit Board
Main card internal programming is accomplished via three 4-position
printed circuit board (PCB) mounted dipswitches mounted just to the left
of the module’s faders.
For main PCB programming, we will assume you are holding the removed
module upright, component side towards you, with gold-plated card fingers to
the left and the module faceplate to the right. This will enable you to read the
control legends silkscreened next to each dipswitch. Note when a dipswitch
position is thrown to the right (towards the module’s faceplate) it is ON.
Output Assign Switch Enable
As previously stated (page 2-5 and 3-4), microphone (MMD) and
stereo line (SLD) input modules can have their output assign switches
slave off of the SPD-5 phone module output assign switches. Four-
position dipswitch SW1 (top dipswitch just to the left of the module faders)
enables this feature at the phone module end:
Dipswitch position 1 activates PGM switch control
Dipswitch position 2 activates AUD switch control
Dipswitch position 4 activates UTL switch control
Mutes
When the SPD-5 phone channel ON switch is pressed, it can activate
console mute functions. The first three positions of dipswitch SW2 (just
below dipswitch SW1) determines which of the console’s three mute lines
will be activated:
SW2 position 1 mutes the control room when the phone module is
ON*
SW2 position 2 mutes studio one when the phone module is ON
SW2 position 3 mutes studio two when the phone module is ON
Timer Restart
The console’s digital timer can be programmed to automatically reset
to zero and begin counting up when the module’s ON button is pressed.
SW2 position 4 activates timer restart when the phone module’s ON
switch is pressed*
Tallies
Turning the module ON can activate a remote tally indicator. There are
three tally control lines: on-air, tally 2 and tally 3. The first three positions
of dipswitch SW3 (to the left of the fader) program these functions:
SW3 position 1 activates the on-air tally control line
SW3 position 2 activates tally 2
SW3 position 3 activates tally 3
Remote tallies are
hooked-up to the console
at the Control Room mod-
ule (CRD-5)
Note this feature only
works for turning slaved
assign switches ON; they
will not turn OFF from the
superphone module—this
must be done manually.
*factory default setting
*factory default setting