Owner`s manual

page 7 – 2
RD-12 / March 99
M E T E R O U T P U T M O D U L E
Meter Output Module
(MOD-5)
Module Overview
Each RD-12 console has one meter output module, which drives the
console’s three pairs of left-right VU meters: PGM, AUD and UTL.
Recessed front panel trim pots calibrate the three meter pairs. A VU
TRIM cover strip (not shown) can be used to prevent trimpot access once
calibration is set.
At the bottom of module are the timer control buttons (the timer
display is mounted in the righthand end of the console meterbridge):
AUTO – enables timer restart functions from programmed input modules
S/S – Start/Stop
RESET - return to zero (if the timer is stopped it will hold at zero; if it is
running it will reset to zero and immediately begin counting up).
HOLD – when held down freezes the timer display (the counter keeps on
going); when released the display catches up to the current count.
There are two 12-pin AMP type connectors for factory use only. They send
the module’s VU and timer control signals to the meterbridge (a factory-
provided cable runs from those connectors to the back of the meterbridge).
Internal Programming Options
There are no internal programming options on the MOD-5 module.
Hook-ups
All I/O connections from the MOD-5 meter output module are “inter-
nal” to the console (i.e., used to route VU and timer signals to the
meterbridge) and not normally applicable to end customer use.