Technical data
Chapter 4 Deployment Manual VIPA System 300S SPEED7
4-44 HB140E - CP - RE_343-1EX71 - Rev. 09/46
There are two options to start the diagnostic tool:
• Via Windows-START menu > SIMATIC ... NCM S7 > Diagnostic
• Within the project engineering res. the hardware configuration via the
register "Diagnostic" in the "Property" dialog with [Execute].
The working surface of the diagnostic tool has the following structure:
The
navigation area at the left side contains the hierarchical listed
diagnostic objects. Depending on CP type and configured connections
there is an adjusted object structure in the navigation area.
The
information area at the right side always shows the result of the
navigation function you chose in the
navigation area.
Navigation area Information area
A diagnostic always requires an online connection to the CP you want to
control. For this click on
at the symbol bar. The following dialog window
appears:
Set the following parameters under destination station:
Connection...: Ind. Ethernet TCP/IP
Station addr.: Enter the IP address of the CP
Module rack/slot:
Enter the
module rack and slot of the CP 343 that you’ve placed at the 2.
slot.
Set your PG/PC interface to TCP/IP...RFC1006. Via [OK] you start the
online diagnostic.
Start NCM
diagnostic
Structure
No diagnostic
without
connection