Technical data

Chapter 4 Deployment Manual VIPA System 300S SPEED7
4-28 HB140E - CP - RE_343-1EX71 - Rev. 09/46
You receive the following graphical display for every PLC station and their
component. By selecting the single components, the context menu offers
you several functions:
1
Station
This includes a PLC station with rack, CPU and communication
components. Via the context menu you may configure a station
added from the
net objects and its concerning components in
the hardware configurator. After returning to NetPro, the new
configured components are shown.
2
CPU
A click onto the CPU shows the connection table. The
connection table shows all connections that are configured for
the CPU.
3
Internal communication components
This displays the communication components that are available
in your CPU. For the SPEED7-Net-CPUs are configured as
CPU 318-2DP the internal components do not show the CP.
Due to this, the CPs that are included in the 31xSN/NET-CPU
must be configured as external CPs behind the really plugged
modules. The CPs are then also shown in NetPro as external
CPs (4, 5) in the station.
4
Ethernet PG/OP channel
The internal Ethernet CP must always be configured as 1. CP
in the hardware configuration. This CP only serves the PG/OP
communication. You may not configure connections.
CPU
318-2
DP MPI CP
343-1
CP
343-1
Station 1
1
1 2
4
3
5
5
CP 343
If exists the internal CP 343 of a CPU 31xSN/NET must always
be configured as 2. CP in the hardware configuration after the
Ethernet PG/OP channel. Else start here to configure and
connect every Ethernet CP 343S-NET - SPEED-Bus as
Siemens CP 343-1 (343-1EX11). The sequence follows the one
at the SPEED-Bus from the right to the left.
NetPro offers you the option to link-up the communicating stations. You
may link-up the stations via the properties in the hardware configuration or
graphically via NetPro. For this you point the mouse on the colored net
mark of the according CP and drag and drop it to the net you want to link.
Now the CP is linked up to the wanted net by means of a line.
CP
343-1
CPU
318-2
DP MPI CP
343-1
Station 1
Industrial Ethernet
CPU
318-2
DP MPI CP
343-1
Station 1
Industrial Ethernet
CP
343-1
PLC stations
Link up stations