Technical data
Chapter 4 Deployment Manual VIPA System 300S SPEED7
4-22 HB140E - CP - RE_343-1EX71 - Rev. 09/46
The modules at the right side of the CPU at the standard bus are
configured with the following approach:
• Include your System 300 modules at the standard bus in the plugged
sequence starting with slot 4.
• Parameterize the CPU res. the modules where appropriate. The
parameter window opens by a double click on the according module.
Module
CPU 318-2
DP
MPI/DP
DI
DO
DIO
AI
AO
Standard bus
Slot
1
2
X2
X1
3
4
5
6
7
8
9
10
11
Standard bus (serial)SPEED-Bus (parallel)
CPU 31xS
DIDO
Ethernet
CP 343
DI DO DIO AI AOAIDIO
Ethernet PG/OP
CP343
(CPU 31xSN/NET)
For the internal Ethernet PG/OP channel that every SPEED7-CPU
includes, you have to configure a Siemens CP 343-1 (343-1EX11) always
as 1. module below the really plugged modules.
If exists the integrated CP 343 of the CPU 31xSN/NET is also configured
and connected as CP 343-1 (343-1EX11) but always below the before
configured PG/OP channel. Else start here to configure and connect every
Ethernet CP 343S-NET - SPEED-Bus as Siemens CP 343-1 (343-1EX11).
Module
CPU 318-2
DP
MPI/DP
DI
DO
DIO
AI
AO
343-1EX11
343-1EX11
Standard bus
Slot
1
2
X2
X1
3
4
5
6
7
8
9
10
11
Ethernet PG/OP channel
CP 343 (only CPU 31xSN/NET)
Standard bus (serial)SPEED-Bus (parallel)
CPU 31xS
DIDO
Ethernet
CP 343
DI DO DIO AI AOAIDIO
Ethernet PG/OP
CP343
(CPU 31xSN/NET)
Open the property window via double-click on the CP 343-1EX11. Enter
"General" and click at [Properties]. Type in the IP address, subnet mask
and gateway for the CPs and select the wanted subnet.
Project engineering
of the real modules
at the standard bus
Project engineering
of Ethernet PG/OP
channel and CP 343
as 343-1EX11
Set IP parameters