30
Checking battery voltages
. . . . . . . . . . . . . . . . . . . . . . . .
Checking the Control-X battery
• Press the ON and OFF buttons simultaneously, and
release them.
The display briefly shows the battery
voltage of the Control-X; for example:
7.60u
If this falls below 6V the battery should be replaced.
Note that the Control-X automatically switches itself off if no
key has been pressed for approximately 12 seconds.
Checking the battery of other Audio Ltd RMS2020 or
RMS2000 transmitters
• Plug the transmitter into the Lemo connector on the front
of the Control-X without pressing either button.
The display shows the true on-load internal battery voltage
of the unit.
For example:
8.55u
Refer to the User Guide for the product for information about
the minimum voltage requirement of the product.
Note: Although the Control-X display automatically turns off
to conserve battery life, the transmitter will remain on while
connected to the Control-X.
Measuring a battery
• Hold the 9V 6LR61 type battery against the two metal
terminals on the side of the Control-X without pressing
any buttons.
The green indicator will be illuminated and the battery
voltage will be displayed.
For example:
8.25u
If the battery is connected the wrong way round the
indicator will be illuminated.
The display shows:
ReVeRse
Technical specification
. . . . . . . . . . . . . . . . . . . . . . . .
Size 100 x 63 x 24mm
Weight 150g including battery
Battery type 9V 6LR61