User Manual

Control-X Transmitter Controller
88
30
Checking battery voltages
. . . . . . . . . . . . . . . . . . . . . . . .
Checking the Control-X battery
Press the ON and OFF buttons simultaneously, and
release them.
The display briefly shows the battery
voltage of the Control-X; for example:
7.60u
If this falls below 6V the battery should be replaced.
Note that the Control-X automatically switches itself off if no
key has been pressed for approximately 12 seconds.
Checking the battery of other Audio Ltd RMS2020 or
RMS2000 transmitters
Plug the transmitter into the Lemo connector on the front
of the Control-X without pressing either button.
The display shows the true on-load internal battery voltage
of the unit.
For example:
8.55u
Refer to the User Guide for the product for information about
the minimum voltage requirement of the product.
Note: Although the Control-X display automatically turns off
to conserve battery life, the transmitter will remain on while
connected to the Control-X.
Measuring a battery
Hold the 9V 6LR61 type battery against the two metal
terminals on the side of the Control-X without pressing
any buttons.
The green indicator will be illuminated and the battery
voltage will be displayed.
For example:
8.25u
If the battery is connected the wrong way round the
indicator will be illuminated.
The display shows:
ReVeRse
Technical specification
. . . . . . . . . . . . . . . . . . . . . . . .
Size 100 x 63 x 24mm
Weight 150g including battery
Battery type 9V 6LR61