User's Manual
36 | P a g e
IMPORTANT! If one of the above steps (a or b) is not completed, the receiver will remain in the “RESET
NAMES” state indefinitely (system is muted), and it will not automatically back out to normal operating
mode.
Multiple-receiver systems:
Turn down the AF level of the associated mixer or amplifier. Make certain that any AEW transmitters are
turned off. (Other RF-generating devices in the area should be turned on, if possible.)
1. Make certain all the receivers are connected (daisy-chained) with link cables. The receiver with only a
Link In (no Link Out connection) becomes the Master receiver. (See “Link connections” on page [--].)
2. Switch on all the slave receivers first; switch on the Master receiver last. Alternatively, all receivers can
be turned on simultaneously, as when using AC power plug strips controlled by a single AC switch. (If an
AC power or link connection is interrupted, even briefly, all receivers must be turned off and the power-
up sequence repeated to assure complete system control.)
3. Using controls on the Master receiver, follow all the steps listed for single-receiver systems to assign
compatible frequencies for all receivers by using IntelliScan.
4. The display on the Master shows “RESET NAMES”, and the display on each slave shows “SCAN” and the
new frequency. The receivers remain in this state (system is muted) until one of the following steps is
completed to accept the new frequency plan:
a. To accept and use this frequency plan with the currently loaded/named presets, touch the
Mode/Set button. If a user preset was previously loaded on the receiver, the LCD briefly displays
“STORED” and reverts to normal operation. The LCD then displays the previously loaded user
preset or receiver name and the new frequency. (Note: This frequency is now stored with the
associated named preset and is recalled when that preset is reloaded.) If no user preset was
loaded (i.e., the default settings were in effect), the LCD shows “NAME?” and the new frequency.
b.To accept and use this frequency and store it in the special “NAME?” location, hold the
Mode/Set button. The LCD displays “NAME?” on the top line. (Note: Doing this allows a new
frequency to be used without affecting previously stored preset data. However, the receiver
shows “NAME?” instead of the preset’s name.)
To store this frequency along with other settings into one of the user presets, refer to the instructions on
page [--].
Note: These changes affect all linked receivers.
IMPORTANT! If one of the above steps (a or b) is not completed, the Master and all linked slave receivers
will remain in the “RESET NAMES” state indefinitely (system is muted) and will not automatically back out
to normal operating mode.
Note: A “SCAN ERROR” message may be attributable to one or more of the following:
The link connection was broken somewhere in the chain.
The power to one or more of the linked receivers was turned off.
Not enough available frequencies existed for IntelliScan to assign all receivers a frequency. If
IntelliScan cannot locate enough available frequencies, it will set as many as it can on the linked
receivers.