User's Manual

30 | P a g e
LOAD: DEF DEF (default), PRSET1 through PRSET5 Yes
STORE: PRSET1 PRSET1 through PRSET5 Yes
Quit (exit Menu) QUIT Press Set once to exit --
* Continue in the same Up/Down direction and choices “wrap around” to the other end of the range.
** Additional 6 dB pad switch on capsule.
† Band C: 541.500; Band D: 655.500 MHz
Table 3. Handheld Transmitter Functions
Transmitter Setup
Battery Selection and Installation
Each transmitter uses two 1.5V AA batteries, not included. Alkaline type is recommended. Always replace
both batteries. Make certain the transmitter power is Off before replacing batteries.
UniPak™ Transmitter Battery Installation
1.Open the battery compartment door as follows: Slide door lock down to the unlocked position. Pinch the
release arrows together to open the compartment. (Fig. L)
2. Observe correct polarity as marked on the metal contacts on the door and carefully insert two fresh
1.5V AA alkaline batteries (Figure M).
3. Close the door, making certain the latch clicks securely in place.
4. Slide the door lock up to the locked position.
Figure L [NOTE: This is new from 3000 Series owner’s manual]
Figure M [NOTE: This is new from 3000 Series owner’s manual]