Specifications
Receiver Contr
ols and Functions 
(Continued)
Meter Hold
When activated (“METER HOLD”), this function permits the bar
meters in the LCD window to captur
e and display the 
highest-
level “
AF” audio modulation (a solid bar) and the lowest-level
“
RF” signal (a flashing bar) received from the transmitter. This
is particularly useful when setting up the system initially, 
performing a sound-check, or diagnosing operating problems.
The default setting is Off (“
METER NORMAL”).
When the Meter Hold is On, it is possible to reset it – to obtain
a new set of RF and AF readings – without turning it off-and-on
using the Menu/Edit functions. Simply press the transmitter’s
Power/Mute button once (to mute the transmitter) and 
wait 
until the r
eceiver’s Alert light comes on
, indicating the Mute
condition. Then pr
ess the transmitter’s Power/Mute button
once again, to un-mute the transmitter. 
After the Alert light
goes out
, a new set of min/max RF/AF readings will be 
indicated on the bar meters. (Note that, depending upon the
digital updating-and-confirming sequence of the Mute condition
data from the transmitter, it can take from a few to many 
seconds for the Alert light condition to change. 
The Meter Hold
readings are not reset until the Alert light has turned on,
then off.
)
Note: Any or all of these receiver functions may be stored to, or
loaded from, one of the five user presets.
Using "PRESET" Store and Recall
There are two aspects to Preset operation: Storing a particular
collection of settings for future use (“
STORE”), and recalling a
stored collection of settings (“
LOAD”). All Artist Elite receivers
and transmitters permit the storing and recalling of up to five
user-defined Preset combinations—with customized names, if
desired—plus the recalling of the factory-defined Default
(“
DEF”) settings.
While the standard Preset names (“
PRSET1” – “PRSET5”) can
be used, customized receiver and transmitter identification can
simplify system operation, especially in larger systems. For
example, a guitar channel’s Rx Name could be “
GUITAR”, while
the transmitters for the performer’s two different guitars could
be named “GTR-1” and “GTR-2”.
To stor
e Preset configurations:
1. Touch the Mode/Set button once to move to Menu mode.
2.
T
ouch
the Up ar
r
ow twice to move to “
PRESET” in the LCD 
window. (The second line of LCD will show currently loaded 
presets.)
3.
T
ouch
the Mode/Set button once. “LOAD” (or “STORE”) 
appears in the LCD.
4.
T
ouch
the Up or Down ar
r
ow once, if needed, to change the 
selection to “
STORE.”
5.
Hold the Mode/Set button until “PRSET1” (or the name 
of the cur
rently loaded Preset) appears on the second line 
of the LCD.
6.
If desir
ed, 
touch the Up or Down ar
r
ow to cycle thr
ough the 
available choices: “
PRSET1” thr
ough “
PRSET5” (or their 
previously changed names).
7. Accept or enter a name for the Preset:
a. To accept the 
standard name “PRSET1“ – “PRSET5” (or 
previously stored name) for a new Preset configuration 
and to update (overwrite) any previously stored 
configuration choices:
a1. At the desired choice, 
hold Mode/Set until the first 
character blinks, giving an opportunity to change the 
name.
a2. To accept the standard (or existing) name, 
hold the 
Mode/Set button again until “
STORED” appears in the 
window. This stores the standard or existing Preset 
name with the associated function choices and returns 
the unit to normal operation. The name of the stored 
preset will appear in the top line of the display.
b. To enter a 
custom name for a Preset:
b1. At the desired choice, 
hold the Mode/Set button. 
The first character blinks.
b2. Using the Up or Down arrow, move through the 
available characters (see box below) until the desired 
character is reached. 
Touch an arrow button for single 
steps, or 
hold it down to scroll through the characters 
at increasing speed.
b3.
T
ouch
the Mode/Set button once to accept the first 
character and move to the second character, which now
is blinking. Use an Up/Down arrow button to find the 
desired second character; 
touch the Mode/Set button
once to accept it and move to the third position. Repeat 
this selection process until the character for the sixth 
position has been selected.
b4. Once the sixth character has been selected as desired, 
hold the Mode/Set button until “STORED” appears in 
the window. This stores the custom Name with the 
associated function choices and returns the unit to 
normal operation. The display shows the custom name 
in the top line.
Note: If a correction or change is desired while entering 
characters, simply 
touch the Mode/Set button once when 
the sixth (last) character has been reached. The window will 
flash “
ESCAPE.” Touch the Mode/Set button once more to 
start the name-entry process over at the first character. (To 
leave any characters as they are, simply 
touch Mode/Set 
once to skip over them.)
16
Available receiver Name character choices:
A …through… Z,
__ (underscore) … (
space) … 
[ (
left bracket) … ] (right bracket),
* … + … -- … / ,
0 …through… 9,
| … < … > … ?