User manual

If the speaker zone is not in the same room as the
amplifier you can supervise the output with the
connectors on the terminal strip marked as
MONITOR OUTPUT.
There are several options.
1. Connection of an ear phone
at the terminal output 600W and 1V.
2. Connection of a speakers
at the terminal output 8W and 1W.
22
EN
ic audio
MONITOR OUTPUT
Volume Controller
MONITOR OUTPUT
20060 651
You can connect up to 12 Paging MIC’s at the rear of
the Mixer Amplifier in parallel operation.
The amount of the NF-input-signal (INPUT -/+)
is suitable from -40dB up to 0dB and is exucted by
the input controller. The chime can be activated by
a contact transmitted to the GND connection.
The internal power supply of the Mixer Amplifer
will operate the paging MIC’s.
The maximum power consumption should not be
higher then 1,5 Ampere.
The Priority setting activates the 100 V output
(Speech Only) and will override all other input signals.
Paging MIC (12-pin)
Device Functions
- Rearside -
MONITOR OUTPUT
Paging MIC
20060 651
Adaptor (SUB-D 9 to clamp) for
connection of the paging microphones
M-E 01 and M-E 04 is included in the delivery.
Please note:
For operating the paging microphones
you have to put the switches in the
following positions: