User's Manual
- 9 -
A10-RX User Guide
Main Menu
Selections Icon Description Channel or
Global
Options
Exit
Returns to the main display screen.
Frequency
Sets the transmitter’s frequency. Frequency
selection and channel increments change based on
the region of operation to which the unit is set.
Channel • TV Channel Increments
• Sub Channel Increments
• Tune: Frequency
Increments in 25 kHz steps
Outputs
Enters the Outputs sub menu. • Maximum Level
• Audio Polarity
• Mode
• Test Tone
Scan
Enters the scan function. Scanner indicates the RF
activity. Scans can either be in 25 MHz increments
or across the full range of the receiver.
Global • 1-10 - scans subsections of
the tuning range
• Full - scans entire tuning
range of system
Privacy
When active the transmitter sends its signal
encoded with a four-digit privacy key set at the
transmitter. The same four digit key needs to be set
on a receiver to receiver to receive the signal.
Channel • On - enter key
• Off - encryption cleared, set
to 0000 to deactivate
Settings
Enters additional settings sub menu. • Screen Brightness
• Screensaver
• Orientation
• LEDs
• User Groups
• TV Channel Map
System
Enters additional settings sub menu • Power
• Restore
• Info
Outputs Sub-Menu
Selections Icon Description Channel or
Global
Options
Exit
Returns to the main menu
Max Level
Selects the maximum analogue output level. Output
level based on a 0 dBFS signal sent from an A10-TX
transmitter.
Channel • +14 dBu
• +2 dBu
• -10 dBu
• -22 dBu
Audio Polarity
Selects the polarity of the balanced output signal. Channel • Normal
• Inverted
Mode
Chooses the audio output type of the A10-RX.
When the A10-RX is set to AES the channel 2 XLR
connection is not used.
Global • Analogue
• AES
Test Tone
Activates a 1 kHz tone oscillator sent directly to the
outputs. tone
ª This disrupts the output from a linked A10-TX
transmitter.
Channel • -18 dB