Installation guide
ARCHITECT
Model 1280 EQ • Model 1260 
Model 1680 EQ • Model 1660
Installer’s Guide
™
5
 Bus Select Switches – The switches below 
each zone’s local input jacks select the input 
source for that amplier zone. If the switch 
is in the “Local” position, the zone receives 
audio signals from the local input. If the 
switch is in “Bus 1” or “Bus 2”, audio signals 
come from the appropriate “Bus” inputs. 
Whenever a Bus Input is selected, the zone 
input can be remotely triggered to the local 
input using the 12 volt Local Trigger input 
(see #6 on previous page).
 Local Inputs - These unbalanced RCA in-
puts connect to your preamplier’s outputs. 
Any standard line level audio signal can be 
connected to these inputs.
  AC Power Fuse – The Architect is designed 
with several layers of protection circuitry. 
The main AC power fuse is here just in case 
something really awful goes wrong. There 
are no internal fuses in this amp.
  Master Power Switch – This switch shuts 
o the main AC power. Normally the only 
time you need to turn the master power 
switch o is if the system is going to be shut 
down for an extended period of time.
  Remote Power Control – This three pin 
connector allows you to remotely turn on 
the Architect. You can either use a contact 
Guided Tour
closure between the Trigger In and the 
+12V output or an external 12 volt trigger 
between the Control In and Ground termi-
nals. The +12 volt output is not designed to 
power other pieces of equipment.
  Ground Lift Switch – This switch selects 
the level of isolation between the audio 
signal ground and your AC earth ground. 
In normal operation this switch should be 
in the Ground position, but if you run into 
trouble with an AC ground hum, try the oth-
er two settings for the best operation. For 
your safety, the chassis is always connected 
to the earth ground regardless of the switch 
setting.
  Remote Power control (1/8” jacks) - These 
mono 1/8” jacks are wired parallel to each 
other and work in conjunction with the 
3-pin remote power connector. Either 1/8” 
input can receive a 12-volt trigger which 
will turn-on your Architect amplier. This 
will then allow the unused jack to output 12 
volts that can be used to turn-on a second 
amplier. If your using the 3-pin connec-
tor to trigger the Architect, both of the 1/8” 
jacks can provide output trigger
15
14
13
12
11
 
11
12
15 14
13
13