Installation guide
ARCHITECT
Model 1280 EQ • Model 1260 
Model 1680 EQ • Model 1660
Installer’s Guide
™
  D?  Model ID  
    three digit number
  B?  Signal sense 
    0=Defeated, 1=Active
  H?  Header/Footer Status 
    0=None, 1=Include 
  See next page for   
    header formats
  IP? 
IP address and port set 
    for notications.  
    Active telnet session  
    not required for  
    notications.
  AP?  Automatic protect 
    notication  
    0=o, 1=on
  AC?  Automatic change 
    notication 
    0=o, 1=on
  PB?  Physical bypass 
    1= bypass switch 
    engaged 
    0=not engaged
  M?  Binary string showing 
    all zones mute   
    status
    0 = Mute  
    1 = Active (unmuted) 
    (i.e. ‘001000’ –  
    zone 3 is unmuted)
  S?  Protection status   
    (zone 1-8 and Amp) 
    1=Normal/Active 
    0=Mute/Standby 
    2=Protect 
    3=Short circuit
  T?  Temperature  
    (zone 1-8) 
    0=Cool, 1=Normal 
    2=Warm     
    3=Thermal protection 
    4=Channel muted
  P?  Main power status – 
      0=o, 1=on
  V?  AC Line voltage –   
    0 = Low  
    (less than 105 VAC) 
    1 = Normal 
    2 = High 
    (more than 125 VAC)
  L?  Protection data log 
    (comma delimited   
    text) 
  See next page for log 
  formats
Inquiry Commands
17
Ethernet Connectivity