Installation guide

®
16
Ethernet Connectivity
B0 Defeats signal sense
B1 Signal sense Active
H0 No header and footer
to inquiries
H1 Included header and
footer
SIP Set IP address for
notication messages.
Address followed by
colon and port number
AP0 Automatic protect
notication o
AP1 Automatic protect
notication on
AC0 Automatic change
notication o
AC1 Automatic change
notication on
CL Clear all logs
P0 (zero not O’)
Main Power O
P1 Main Power On
M1 Mute channel 1-2
M2 Mute channel 3-4
M3 Mute channel 5-6
M4 Mute channel 7-8
M5 Mute channel 9-10
M6 Mute channel 11-12
M7 Mute channel 13-14
M8 Mute channel 15-16
MA Mute all channels
U1 Unmute channel 1-2
U2 Unmute channel 3-4
U3 Unmute channel 5-6
U4 Unmute channel 7-8
U5 Unmute channel 9-10
U6 Unmute channel 11-12
U7 Unmute channel 13-14
U8 Unmute channel 15-16
UA Unmute all channels
Control Commands
The commands are broken into two groups: Control and Inqui-
ries. The Controls issue instructions to the Architect for power
control and channel muting; the Inquires return the status of
amplier channels, AC line voltage, the amplier temperature,
and the failure data log.