Unit installation

46
8.3 CTM City Tie Module
The CTM is designed to interface between a control panel and a local city tie box. The interface from the
control panel is via a 24VDC signal circuit. This module is intended for connection to the control unit at the
protected premises.
Ratings:
City Tie Module
Operating Voltage 24 VDC
Standby Current 2 mA
Alarm Current 1.5 A (less than 10 milliseconds) for Model DC-2A Master Box
UL listed File S3610
City Tie Box
Series type Coil Resistance 14.5 ohms
The CTM is wired as shown below.
Note:
The CTM is separately listed equipment. Refer to the installation and wiring instructions provided
with the unit.
When connecting the CTM module to any of the bell (NAC) circuits, that circuit(s) must be
programmed as a strobe circuit
Figure 35: CTM City Tie Module Wiring