Installation and Operation L 1 2 3 4 5 6 7 8 INPUT L OUTPUT 9 10 11 12 13 14 15 16 INPUT R 1 2 3 4 5 6 7 8 ETHERNET USB SPEED R OUTPUT OUT TO AMPLIFIER ZONES 9 - 16 L LINK OUT TO AMPLIFIER ZONES 1 - 8 R L 9 10 11 12 13 14 15 Model ADX-1616 Audio Matrix 16 800-322-8346 • 859-233-4599 www.audioauthority.com IR R RS-232 SERIAL INPUT 1- SLEEVE = +12V 2- RING = GROUND 3- TIP = SIGNAL 3.
ADX Serial Number Custom Installer Telephone Number 2
Installation and Operation Manual Model ADX-0808 Model ADX-1616 Audio Matrix Systems Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Warnings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Panel Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Getting Started. . .
Introduction The ADX is the industry’s most controllable analog audio matrix, featuring multiple control interfaces and an attractive design that is sure to compliment any equipment rack or shelf. Capable of distributing sixteen analog audio channels to sixteen destinations, it is the perfect solution for analog audio distribution in both small and medium size installations.
9 1 10 2 11 3 12 4 13 5 14 15 7 16 8 INPUT K INPUT ADX Series Audio Matrix Switcher Analog Audio Output Jacks 1-16 for ADX-1616 or 1-8 for ADX-0808 13 6 M 12 5 DB25 Connector(s) for future use 11 4 B Analog Audio Input Jacks 1-16 for ADX-1616 or 1-8 for ADX-0808 10 3 Favorite Selection Button Group Selection Button Audio Matrix Switcher A INPUT INPUT L 9 2 F E 16 8 Multi Function Knob 15 7 K R L R 1 Vacuum Fluorescent Display (VFD) C L Front Panel
Getting Started • Confirm that nothing is missing from your shipping carton. Refer to Carton Contents on page 4. • Record the serial number (found on the product rear panel) in the space provided on the inside of the front cover of this manual for easy reference. • Activate your warranty and receive future upgrade notifications by registering your purchase on our website, www.audioauthority.com/register.
Installation The ADX is easy to set up for both simple and advanced installations. Perform the following steps. Installing the ADX The ADX is conveniently designed so that it may be installed either on a shelf or in a standard 19-inch equipment rack. If rack mounting, remove the feet and the cover screws adjacent to the front panel of the unit. Reuse the cover screws to mount the Model 1192A rack adapters supplied with the ADX. Be sure to place a spacer under the adapters at every screw location.
Advanced Setup and Remote Control Options Using the RS-232 Port. System controllers and PCs can send all setup and control commands as well as receive feedback via the RS-232 serial port. • Important: If a PC is connected directly to the ADX RS-232 port, use a standard serial cable. • The baud rate is set to 9600 by default, but this may be changed using the Front Panel Menu screen “Serial”. The other connectivity parameters are fixed to 8 data bits, no parity, 1 stop bit, and no flow control.
DHCP If DHCP is enabled on your network, simply connecting the ADX to the network with an existing DHCP server will enable it to obtain all necessary information. DHCP is enabled on the ADX by default. Static addressing connected directly to a PC The ADX must be given an IP address which will not conflict with the PC. Go to the network settings (which are found in control panel -> network -> local connection properties of a PC running Windows XP).
Operation Front Panel The front panel is operated by touching the sensitive key areas: Group E , Favorite F , All G , Menu H , Back I , and Dim J to select the respective sub-menu. Once the desired screen has been selected, rotate the Multi Function Knob D to navigate to the item you want to change and press the knob to select that item. The previous selection is marked with a solid arrow “”, and any others marked with an open arrow “.
Dim Button J This button toggles through four predefined brightness levels for the VFD and keyboard LED indicators. After a five minute period, the VFD will enter a screen saver mode and turn off. The power and button LED’s will remain on at a very low level to show that the unit is receiving power. Any key press or knob adjustment will cause the system to return the VFD and LED indicators to the last selected brightness level.
Export File With a USB 1.1 or USB 2.0 drive connected to the USB port O on the rear panel of the ADX, simply follow the on screen instructions to export to the default file name, “config.adx”. If the file is already present, you will be prompted to overwrite it. Note – The USB port is v1.1 and v2.0 compatible. There is a small delay when inserting a USB drive to identify the device and mount the file system.
Appendix A: Serial Commands Description Command Structure Example Command(s) Example Output Result Switching and Zone/Source Related Switch a zone output to a source input. [CO##I##] [CO1I2] (CO1I2) Zone output 1 is connect to source input 2. Switch all zones to a single input source. [CXI##] [CXI4] (CXI4) All zone outputs are connected to source input 4. Switch to a favorite zone/source configuration.
Network Settings Adjustment Query current network (Ethernet) settings [QE] [QE] (DHCP1) (IP0.0.0.0) (NM0.0.0.0) (GW0.0.0.0) (MAC00-00-5E-A800-D3) DHCP status, IP address, subnet mask, gateway, and MAC address are displayed by this command. Enable or disable dynamic host configuration protocol (DHCP). [DHCP#] [DHCP1] [DHCP0] (DHCP1) (DHCP0) DHCP is enabled (1) or disabled (0). It is not possible to statically set address while DHCP is on. Define the static IP address. [IP###.###.###.###] [IP192.
Favorites (see switching for activating a favorite configuration) Query favorite. [QF##] [QF10] (F1AO1I3) (F1AO3I4) (NF1”Favorite 1 Name”) (QF10) Query favorite membership and settings. See the favorite adding and naming commands for how to read the results. Add a zone/ source combination to a favorite. [F##AO##I##] [F1AO3I2] (F1AO3I2) Add to favorite 1 the zone 3, source 2 combination. Remove a zone/source combination from a favorite. [F##RO##] [F1RO3] (F1RO3) Remove zone 3 from favorite 1.
Appendix B: Firmware Update Procedure • The latest version of firmware is available for download from www.audioauthority.com/page/software. • Save a copy of the firmware file to a USB drive. • Power cycle the ADX, and press the knob just after power turns on and the screen displays “Press Knob to Update Firmware.” • Insert the USB drive into the back of the unit. • Follow the on screen prompts and select the downloaded file.
Specifications Audio Parameters Analog/Digital Analog Digital Input/Output Type N/A Input Impedance 100K Min Load Impedance 10K Multi-channel Digital N/A Frequency Response 10-25kHz S/N Ratio 82dB THD+Noise 0.02% Crosstalk -85dB Power Agency Approvals FCC DC Input Connector 5.5 x 2.1mm DC Input Voltage/Polarity 18V Center Positive Max DC Input Current 600mA/1.
48 Mercer Road, Lexington, Kentucky 40511-1071 Phone: 859/233-4599 • Fax: 859/233-4510 Customer Toll-Free USA & Canada: 800/322-8346 Website: http://www.audioauthority.