Specifications

SYSTEM COMPONENTS ACCESSORIES
EIB / KNX BUS CABLE


ORDER CODE
TECHNICAL FEATURES
Double-bus cable 2x2x0, 8 coils 100mt
Double-bus cable 2x2x0, 8 coils 500mt
Double-bus cable 2x2x0, 8 coils 1000mt
Single bus cable 1x2x0, 8 coils 100mt
Single bus cable 1x2x0, 8 coils 500mt
Single bus cable 1x2x0, 8 coils 1000mt
3v LED indicator light blue wiring red-black - 20 pcs
3v LED indicator light blue wiring red-black - 60 pcs
3v LED indicator light white wired red-black -20 pcs
3v LED indicator light white wired red-black -60 pcs
Wago connector Red / Black Box 10 pcs
Wago connector Red / Black Box 500 pcs
CV00A01KNX
CV05A01KNX
CV10A01KNX
CV00A02KNX
CV05A02KNX
CV10A02KNX
LD00A01ACC
LD00A02ACC
LD00A11ACC
LD00A12ACC
WG00A01ACC
WG00A02ACC
Inner conductor:
Solid bare copper wire
Construction:
1x2x0,80 mm or 2x2x0,8 mm
Dielectric:

(LSZHFRNC)
Colours:
Red, Black or Red, Black, Yellow, White
Outer Jacket

(LSZHFRNC)
Classified
CEI 20-11 M1
According to:
IEC 60332-1, IEC 61034-1, IEC 61034-2,
IEC 60754-1, IEC 60754-2
Diameter
5,20 mm ± 0,20
Colour
Green (RAL 6018)
3V LED INDICATOR
BUS CONNECTOR
Packages of 20 or 60 pcs LED with Blue or White light 3V wired red / black.
BUS Connector Red / Black for EIB / KNX, with direct plug connection. They can be connected up to 4 pairs of wires to a KNX
device can also be used as a branch terminal.
ORDER CODE
ORDER CODE
TECHNICAL FEATURES
TECHNICAL FEATURES
Dimensions
3 mm x 4.3 mm (width and height) and 3.85 mm (radius)
Current: 20 mA
Reverse Voltage: 5 V
Luminous Intensity: 4000 Min - Max 9000mcd
Wire 22 to 18 AWG (0.6 - 1 mm)
EN detected voltage 100V
Rated current 6A
Stripping length from 5 to 6 mm
Weight 1.6 gr
Dimensions alt. x width. x depth.: 11.5 x 10 x 10 mm
5958
Actuators
BUILDING
USB - IP - IP ROUTER INTERFACE / KNX
These devices allows the communication between computers, IP devices with the KNX bus system.
- KNX / USB 1.1 or 2 interface for direct connection to your computer
- KNX / IP interface for direct or LAN connection for programming or supervision of the KNX system.
- KNX / IP router, is used for connectionless and simultaneous transmissioni of KNX telegrams to several devices. It can
also be used as a programming interface KNX bus system
ORDER CODE
TECHNICAL FEATURES
USB / KNX Interface
IP / KNX Interface
IP ROUTER / KNX Interface
IN00A02USB
IN00A02IPI
IN00A01RIP
Dimensions
Weight: 100 g Dimensions: H: 90 x W: 36 x D: 65 mm
Mounting
Width (UM = 18mm) 2 mod. DIN
Connections for USB / KNX
Bus line with bus connecting terminal, wire max section 0,8mm²
USB type B socket
Connections for Interface IP - IP Router / KNX
Bus line bus connecting terminal, wire max section 0,8mm²
Complementary power supply: 2-wire screw terminals with
max section 4 mm²
Network RJ45 LAN jack
Supply
From the KNX bus 21 .. 30 VDC SELV <300 mW
Additional 5V DC <200 mW through USB for
KNX/USB interface
Additional 12/24 V DC for KNX/IP interface
Additional 12/24 V DC for KNX/IP Router
Indicators
1 green LED active connection

POWER SUPPLY 160 - 320 - 640 MA
BUS LINE COUPLER KNX
Power supply for generating bus voltage on a line with a maximum current of 160, 320 or 640mA according to the model.
With integrated choke to decouple the power supply voltage from the bus. Connection with screw terminals. Mounting on
DIN rails EN 50022. Connection via bus terminal.
LC00A01KNX can be used as a line coupler to connect a line to a main line or as a backbone coupler to connect a main line

activating by a frontal button which is very useful in commissioning / installing phase or during system tuning.
ORDER CODE
ORDER CODE
TECHNICAL FEATURES
TECHNICAL FEATURES
160 mA Power Supply
Bus Line Coupler KNX
320 mA Power Supply
640 mA Power Supply
PS00C01KNX
LC00A01KNX
PS00B02KNX
PS00B03KNX
Dimensions
H 90 x W 72 x D 58 mm for PS00C01KNX & PS00B02KNX
H 90 x W 110 x D 58 mm for PS00B03KNX
Mounting
Width (UM = 18mm) 4 mod. DIN (PS00B01KNX & PS00B02KNX)
6 mod. DIN (PS00B03KNX)
Connection
Bus line connecting terminal, wire max section 0,8mm²
Power supply 230V with plug-in terminals, cable max section
2,5mm²
Supply
Line voltage: 230V AC, 50-60Hz
Dimensions
H 80 x W 36 x D 58 mm
Mounting
2 mod. DIN
Connections
KNX/EIB instabus terminal for superordinate and subordinate
line
Supply
From KNX bus 21..32 V DC SELV
Control elements
1 button: Programming for ETS
Indicators
LED Bus Stat Main green - Off: main line error - On: main line ok
LED Bus Stat Main red - On: manual overwrite active
LED Bus Stat Sub green - Off: sub line error or not connected
On: sub line ok
Output voltage
29 ± 1V DC
Output current / model
Max 160mA, 320mA, 640mA with protection
against short circuit
Control elements
1 switch to reset output power
Reports
1 green LED for power bus
1 red LED for overload warning






LED Group Address - Routing of group telegrams - Off: main

route all - Red: block
LED Physical Address - Routing of physical addressed

active - Green and yellow: route all - Yellow: block