Technical data

61
As can be seen from g. 241_096, the
electrical mid point does not
correspond to the mechanical mid
point.
In order that a linear output signal
can be produced, this is compen-
sated by the evaluation electronics in
the control unit J556.
A precise t of the selector fork to the
hydraulic regulator (see description
of hydraulic regulator) and perfor-
mance of basic set-up are also
preconditions for the problem-free
function of the additional shift stage.
When carrying out basic set-up, the
control unit J554 is adapted to
recognise the mechanical end
positions of the selector fork.
Further information can be found in
the Service chapter under Basic set-
up.
Measuring points on the travel
sensor
P
rimary coil (channel A)
Red measuring probe at pin 2
Black measuring probe at pin 1
Secondary
coil (channel B)
Red measuring probe at pin 4
Black measuring probe at pin 3
Signal map, low range OFF
241_088
A measuring adapter VAS 5258
measures the signals from the
travel sensor system.
Signal map, electrical mid point
241_090