Technical data

59
Example, measured value block 2
:
1st and 3rd position =the smallest or largest measured value in the basic set-up
2nd position = current measured voltage from travel sensor system (signal voltage from
controller J556 to controller J554
4th position = position of shift actuation in mm
Status 1 2 3 4
Low range Off 1.00 V 4.09 V 4.09 V 16.8 mm
Neutral position 1.00 V 2.65 V 4.09 V 8.8 mm
Low range 1.00 V 1.18 V 4.09 V 0.9 mm
241_096
Mechanical mid point
Electrical mid point