Instruction Manual

We reserve the right to change specifications without notice, this is part of our policy to continually improve our products.
Architects’ and Engineers’ Specifications:
The surface-mount loudspeaker shall be a full-range type equipped with a 6.5” driver and fitted with a line transformer allowing it to
be used on 100 Volt distributed line systems. It shall have an RMS power handling of 10 Watt with a maximum power handling of 20
Watt and the frequency response (±3 dB) shall range from 100 Hz to 15 kHz. The sensitivity shall be 96 dB when measuring with an
input signal of 1 Watt at a distance of 1 meter, while the maximum continuous sound pressure level shall be 106 dB. The nominal
dispersion shall be a 140° conical coverage pattern at -6dB (average 100 Hz - 10 kHz). The loudspeaker shall fitted with a
multitapping line transformer with tappings for 6 Watt and 3 Watt. Fast and safe connection of the system shall be possible using
SnapConnect™. The speakers frame shall be constructed in high quality ABS material and the front shall be finished through a
borderless and finely perforated steel grill. It shall come available in both white (RAL9003) and black (RAL9005) colours and custom
painting shall make it blend-in with any environment. The speaker shall have a diameter of 206,5mm, a depth of 95 mm and the
weight shall not exceed 1,08 kg. The speaker shall be fixed to the wall with two screws spaced 130 mm apart.
AUDAC - NELO706 - 01/04/2022 08:09 UTC
Page 3 of
6