69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 1 Wednesday, June 29, 2011 1:15 PM System Installation Guide EConnect™ Wireless Thermostat Kit TA7210 With Equipment Interface Module Installation guide for: • Wireless equipment interface module • EConnect™ wireless thermostat • Wireless remote control • Wireless outdoor air sensor IMPORTANT INSTRUCTIONS ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 2 Wednesday, June 29, 2011 1:15 PM Installation Guide System installation at a glance 1. The equipment interface module (EIM) allows you to control a baseboard heater, a convector or a fan-forced heater in a 120-volt, 208-volt or 240-volt application from a EConnect™ wireless thermostat.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 3 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Install the Equipment Interface Module (EIM) 2. Determine the location The equipment interface module (EIM) consists of a relay and an antenna. They can be installed either in the wiring compartment of the baseboard heater or in a 4-11/16” square junction box. Install EIMs at a minimum distance of 2 feet (0.6 m) of each other.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 4 Wednesday, June 29, 2011 1:15 PM Installation Guide Installation in a baseboard heater ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect AC power before beginning installation. Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if supply wires are made of aluminum. Disconnect the heater wires from the supply wires. If the heater has a built-in thermostat, remove it.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 5 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Installation in a 4-11/16'' square junction box ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect AC power before beginning installation. Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if supply wires are made of aluminum. 1) 2) Mount the junction box on the wall.
9-2472EF-01 (Aube TA7210 System Installation Guide).book Page 6 Wednesday, June 29, 2011 1:15 PM Installation Guide Connecting multiple heaters to the same EIM N L : For 120V application L2 L1 : For 240V application Blue Black Red Remote junction box or heater wiring compartment The maximum number of heaters per EIM is limited to a maximum load of 12.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 7 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Install batteries in wireless devices Thermostat Install 2 AA alkaline batteries Remote control (optional) Install 3 AA alkaline batteries 3. Outdoor air sensor (optional) Install 2 AA lithium batteries Link all devices to wireless network 4. Start wireless setup Press the EIM Connect button to place it in wireless setup.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 8 Wednesday, June 29, 2011 1:15 PM Installation Guide Link thermostat and EIM to wireless network Perform the following steps on the thermostat: # Display Button Step 1) The Connexion (link) menu appears when you connect the thermostat to wireless network for the first time. Press Ok to select Zone. 2) Press or to change the zone name (optional; see page 17) and press Ok. 3) Press Ok to select Connecter (connect).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 9 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Link additional EIM to wireless network (optional) Perform steps 1 to 6 for each additional EIM. You can link a maximum of 8 EIMs to the wireless network. 1) 2) # If the green light on the previously-linked EIM is flashing, press its Connect button. The green light will become steady. Press the Connect button on the next EIM you wish to link and wait for its green flashing light.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 10 Wednesday, June 29, 2011 1:15 PM Installation Guide Link outdoor sensor to wireless network (optional) 1) Make sure the Connect light on the EIM is flashing (see page 7). If you have more than one wireless thermostat, make sure to activate the wireless setup from an EIM linked to the thermostat. For example, to display the outdoor temperature on thermostat Y, you must activate the wireless setup from either EIM B or C, not A.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 11 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Exit wireless setup 1) 5. Press the EIM Connect button. Its green flashing light will change to a steady green light. If you do not press the Connect button, the EIM will automatically exit wireless setup after 15 minutes of inactivity. 2) Put the cover back on the antenna module. Customize the thermostat 6.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 12 Wednesday, June 29, 2011 1:15 PM Installation Guide Installer setup table Setup function Temperature unit Time format Minimum setpoint Maximum setpoint Programmable mode Keypad lock Zone name Adaptive Intelligent Recovery Anti-freeze Options °C / °F 12h / 24h 5°C to 30°C (41°F to 86°F) 5°C to 30°C (41°F to 86°F) On / Off None / Partial / All 1, ...
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 13 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Minimum and maximum setpoints Follow this procedure to set the minimum and maximum setpoint temperature. # Display Button Step 1) From the installer’s setup menu, press to select Consignes (setpoints) and press Ok. 2) Press Ok to select Min. 3) Press or to change the minimum setpoint. Press Ok. 4) Press Ok to select Max. 5) Press or to change the maximum setpoint. Press Ok.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 14 Wednesday, June 29, 2011 1:15 PM Installation Guide Programmable mode The thermostat is factory-set as a 7-day programmable thermostat. To set it as a non-programmable thermostat, proceed as follows: # Display Button Step 1) From the installer’s setup menu, press to select Horaire (schedule) and press Ok. 2) Press or to select Non and press Ok.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 15 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Keypad lock By default, the keypad lock is disabled. If you leave at Non (no), the homeowner will have full access to all thermostat functions. # Display If you select Part (Partial), the homeowner can change the room temperature only. Button If you select Oui (yes), the buttons will not appear on the screen. To unlock, go to Installer Setup (see page 11).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 16 Wednesday, June 29, 2011 1:15 PM Installation Guide Zone name The zone name is used to identify the thermostat on the wireless remote control. By default, the zone name is Thermostat (zone name 52). If you have a wireless remote control and more than one wireless thermostat, change the zone name of the thermostat to identify it from the other thermostats. For example, if the thermostat is in the living room, set the zone to 31.
69-2472EF-01 (Aube TA7210 System Installation Guide).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 18 Wednesday, June 29, 2011 1:15 PM Installation Guide Anti-freeze When this function is on, the EIM will maintain the room temperature at 13°C (55°F) if it loses communication with the thermostat or if the thermostat sensor is defective. Leave the protection on unless the EIM is installed in a junction box in a separate room from the heater.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 19 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Mount thermostat and outdoor sensor 7. Follow the guidelines below when mounting the thermostat: • Do NOT install the thermostat in an area where it can be exposed to water or rain. • Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimney or stove pipes.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 20 Wednesday, June 29, 2011 1:15 PM Installation Guide Mounting the outdoor sensor (optional) Mount the sensor vertically on an exterior wall, at least 6 inches below any overhang. Choose a location protected from direct sunlight. Place sensor securely in bracket, facing away from wall. Error codes Display 8. Description LO The indoor temperature is below 0°C (32°F). HI The indoor temperature is above 60°C (140°F).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 21 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Verifying the signal strength between the EIM and the thermostat 9. If you have more than one EIM linked to the thermostat, the displayed value is between the thermostat and the first-linked EIM. The signal strength ranges from 0 (no signal) to 10 (strongest). # Display Button Step 1) From the home screen, press and hold the right center button for 5 secs.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 22 Wednesday, June 29, 2011 1:15 PM Installation Guide Remote control or outdoor sensor To replace the remote control or the outdoor sensor, install batteries in the new device (see page 7) and link it to the wireless network (see page 10). If more than one EIM are linked to the same thermostat, you can link the remote control or the outdoor sensor from any one of these EIMs.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 23 Wednesday, June 29, 2011 1:15 PM EConnect™ TA7210 Specifications & replacement parts Thermostat Temperature setpoint range: Temperature setpoint resolution: Temperature display range: Temperature display resolution: Heating cycle rate: Programming: 5°C - 30°C (41°F - 86°F) 0.5°C (1°F) 0°C - 40°C (32°F - 104°F) 0.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 24 Wednesday, June 29, 2011 1:15 PM Installation Guide Regulatory information FCC Compliance Statement (Part 15.19) (USA only) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. FCC Warning (Part 15.
69-2472EF-01 (Aube TA7210 System Installation Guide).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 26 Wednesday, June 29, 2011 1:15 PM Need Help? For assistance with this product please visit www.aubetech.com or call Honeywell Customer Care toll-free at 1-800-831-2823. Automation and Control Systems Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://customer.honeywell.com 69-2472EF-01 06-2011 © 2011 Honeywell International Inc. ® U.S. Registered Trademark. All rights reserved.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 1 Wednesday, June 29, 2011 1:15 PM Guide d’installation du système EConnect MC Ensemble de thermostat sans fil TA7210 Avec module d’interface Guide d’installation pour : • Module d’interface sans fil • Thermostat sans fil EConnectMC • Télécommande sans fil • Sonde extérieure sans fil DIRECTIVES IMPORTANTES DANGER ÉLECTRIQUE Peut provoquer des chocs électriques ou des dommages matériels. Mettre hors tension avant de commencer l'installation.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 2 Wednesday, June 29, 2011 1:15 PM Guide d’installation Installation du système en un coup d’oeil 1. Le module d’interface avec le matériel (MIM) permet de commander une plinthe électrique, un convecteur ou un ventiloconvecteur de 120 volts, 208 volts ou de 240 volts à partir d’un thermostat sans fil EConnectMC.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 3 Wednesday, June 29, 2011 1:15 PM EConnectMC TA7210 Installation du module d’interface avec le matériel (MIM) 2. Déterminer l’emplacement Le module d’interface avec le matériel (MIM) consiste d'un relais et d’une antenne. Ils peuvent être installés soit dans le compartiment de câblage de la plinthe électrique ou dans une boîte de jonction carrée de 4-11/16 pouces. La distance minimale entre les MIMs est de 2 pieds (0.6 m).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 4 Wednesday, June 29, 2011 1:15 PM Guide d’installation Installation dans une plinthe électrique DANGER ÉLECTRIQUE Peut provoquer des chocs électriques ou causer des dommages aux équipements. Mettre hors tension avant de commencer l’installation. Le câblage doit être conforme aux codes électriques locaux. Si les fils d'alimentation sont en aluminium, utilisez des connecteurs CO/ALR conçu à cet effet.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 5 Wednesday, June 29, 2011 1:15 PM EConnectMC TA7210 Installation dans une boite de jonction DANGER ÉLECTRIQUE Peut provoquer des chocs électriques ou causer des dommages aux équipements. Mettre hors tension avant de commencer l’installation. Le câblage doit être conforme aux codes électriques locaux. Si les fils d'alimentation sont en aluminium, utilisez des connecteurs CO/ALR conçu à cet effet. 1) Fixer la boîte de jonction au mur.
69-2472EF-01 (Aube TA7210 System Installation Guide).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 7 Wednesday, June 29, 2011 1:15 PM EConnectMC TA7210 Installation des piles Thermostat Insérer 2 piles alcaline AA 3. Télécommande (facultatif) Insérer 3 piles alcaline AA Sonde extérieure (facultatif) Insérer 2 piles lithium AA Connexion des dispositifs au réseau sans fil 4. Activer la configuration du réseau sans fil Appuyer sur le bouton de connexion du MIM pour activer la configuration du réseau sans fil.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 8 Wednesday, June 29, 2011 1:15 PM Guide d’installation Relier le thermostat et le MIM au réseau sans fil Exécuter les étapes suivantes sur le thermostat : # Affichage Boutons Étapes 1) Le menu Connexion apparaît lorsque vous reliez le thermostat au réseau sans fil pour la première fois. Appuyez sur Ok pour sélectionner Zone. 2) Appuyer sur ou pour changer le nom de la zone (facultatif; voir la page 17) et appuyer sur Ok.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 9 Wednesday, June 29, 2011 1:15 PM EConnectMC TA7210 Relier des MIM additionnels au réseau sans fil (facultatif) Exécuter les étapes 1 à 6 pour chaque MIM additionnel. Vous pouvez relier un maximum de 8 MIMs au réseau sans fil. 1) 2) # Si le voyant vert sur le dernier MIM que vous avez relié clignote encore, appuyer sur son bouton de connexion. Le voyant vert cessera de clignoter.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 10 Wednesday, June 29, 2011 1:15 PM Guide d’installation Relier la sonde extérieure au réseau sans fil (facultatif) 1) S’assurer que le voyant de connexion du MIM clignote (voir la page 7). Si vous avez plus d'un thermostat sans fil, s’assurer d'activer la configuration à partir du bon MIM. Par exemple, pour afficher la température extérieure sur le thermostat Y, vous pouvez activer la configuration à partir du MIM B ou C, et non A.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 11 Wednesday, June 29, 2011 1:15 PM EConnectMC TA7210 1) Sortir de la configuration du réseau sans fil 5. Appuyer sur le bouton de connexion du MIM. Le voyant vert clignotant se transformera en voyant vert fixe. Si vous n'appuyez pas sur le bouton de connexion, le MIM sortira automatiquement de la configuration du réseau sans fil après 15 minutes d'inactivité. 2) Remettre le couvercle sur le module d'antenne.
69-2472EF-01 (Aube TA7210 System Installation Guide).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 13 Wednesday, June 29, 2011 1:15 PM EConnectMC TA7210 Consignes minimale et maximale Pour régler les températures de consigne minimale et maximale. # Affichage Boutons Étapes 1) A partir du menu de l'installateur, appuyer sur pour sélectionner Consignes et appuyer sur Ok. 2) Appuyer sur Ok pour sélectionner Min. 3) Appuyer sur ou pour modifier la consigne minimale. Appuyer sur Ok. 4) Appuyer sur Ok pour sélectionner Max.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 14 Wednesday, June 29, 2011 1:15 PM Guide d’installation Mode programmable Le thermostat est réglé en usine comme un thermostat programmable sur 7 jours. Pour le définir comme un thermostat non programmable, procédez comme suit: # Affichage Boutons Étapes 1) A partir du menu de l'installateur, appuyer sur pour sélectionner Horaire et appuyer sur Ok. 2) Appuyer sur ou pour mettre à Non et appuyer sur Ok.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 15 Wednesday, June 29, 2011 1:15 PM EConnectMC TA7210 Verrouillage du clavier Par défaut, le verrouillage est désactivé. Laisser à Non pour avoir plein accès à tous les réglages du thermostat. # Affichage Sélectionner Part (partiel) pour n’avoir accès qu’au réglage de la température ambiante. Boutons Si vous sélectionner Oui, les boutons n’apparaîtront pas à l’écran. Pour déverrouiller, voir le menu de l’installateur (page 11).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 16 Wednesday, June 29, 2011 1:15 PM Guide d’installation Zone Le nom de la zone sert à identifier le thermostat sur la télécommande. Par défaut, le nom de la zone du thermostat est Thermostat (zone 52). Si vous avez une télécommande et plus d’un thermostat sans fil, changer le nom de la zone du thermostat afin de l'identifier des autres thermostats. Par exemple, si le thermostat est dans le salon, placer la zone à 31.
69-2472EF-01 (Aube TA7210 System Installation Guide).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 18 Wednesday, June 29, 2011 1:15 PM Guide d’installation Hors-gel Lorsque cette fonction est utilisée, le MIM maintiendra la température ambiante à 13 °C (55 °F) s’il perd la communication avec le thermostat ou si la sonde du thermostat est défectueuse. Garder la protection activée sauf si le MIM est installé dans une pièce différente de celle de l'appareil de chauffage.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 19 Wednesday, June 29, 2011 1:15 PM EConnectMC TA7210 Installation du thermostat et de la sonde extérieure 7. Suivre les directives ci-dessous pour installer le thermostat: • Ne PAS installer le thermostat à un endroit où il risque d’être exposé à l’eau ou à la pluie.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 20 Wednesday, June 29, 2011 1:15 PM Guide d’installation Installer la sonde extérieure (facultatif) Installer la sonde à la verticale sur un mur extérieur, au moins 6 pouces au-dessous de tout surplomb. Choisir un emplacement à l’abri des rayons du soleil. Installer la sonde dans son support, avec son dos faisant face au mur. Codes d’erreur Affichage 8. Description LO La température ambiante est inférieure à 0°C (32°F).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 21 Wednesday, June 29, 2011 1:15 PM EConnectMC TA7210 Vérifier l’intensité du signal entre le MIM et le thermostat 9. Si vous avez plusieurs MIM reliés au thermostat, la valeur affichée est celle entre le thermostat et le premier MIM relié au thermostat. L’intensité du signal varie entre 0 (aucun signal) à 10 (maximum).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 22 Wednesday, June 29, 2011 1:15 PM Guide d’installation Télécommande ou sonde extérieure Pour remplacer la télécommande ou la sonde extérieure, installer des piles dans le nouveau dispositif (voir la page 7) et le relier au réseau sans fil (voir la page 10). Si vous avez plusieurs MIMs reliés au même thermostat, vous pouvez relier la télécommande ou la sonde extérieure à partir de n’importe quel des MIMs.
69-2472EF-01 (Aube TA7210 System Installation Guide).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 24 Wednesday, June 29, 2011 1:15 PM Guide d’installation Information sur la réglementation Déclaration de conformité à la FCC (partie 15,19) (États-Unis seulement) Cet appareil est conforme à la Partie 15 des règles de la FCC.
69-2472EF-01 (Aube TA7210 System Installation Guide).
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 26 Wednesday, June 29, 2011 1:15 PM Besoin d’aide? Pour obtenir de l’aide sur ce produit, veuillez consulter le www.aubetech.com ou joindre sans frais le service à la clientèle d’Honeywell au 1 800 831-2823. Solutions de régulation et d’automatisation Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://customer.honeywell.com 69-2472EF-01 06-2011 © 2011 Honeywell International Inc. ® Marque déposée aux É.-U.