User`s guide

Digital Brick
M1 System Management Board User’s Guide 25
for EXT_VOL[3]. Identical switch positions are used for common division factors across all three switches. The table
below applies to any switch.
Note: If an external board has voltages greater than 12 V that need to be monitored, use these options to apply the right
range of voltage to the AV pad.
Digital Brick
You can connect a digital brick on the board. The following signals are common to all digital bricks.
VIN_D
This is the input power to the digital brick. Use alligator clips to connect the VIN_D pin to the input supply of the
digital brick. This pin can provide 9-12 V, depending on the input supply used for the System Management Board.
DIG_BRK_OUT
This is the output voltage of the digital brick. This voltage is monitored by the M1AFS1500-FG484 device using the
AV pads.
VSENSE
This pin is an input to the digital brick that senses back the output voltage of the brick
(Figure 2-11).
Figure 2-11. VSENSE
Table 2-19 · Switch Settings
Numerical Switch Position Internal Voltage as Factor of External Voltage Vext
1Vext * 1
2 Vext * 1/2
3 Vext * 1/4
4 Vext * 1/8
DIG_BRK_OU
T
VSENSE