Specifications

xiii
ATTO Technology Inc. FastStream SC Installation and Operation Manual
RouteDisplay
Displays a combined list of host protocol address to target
destination device mappings.
If
FCMultiNode
is disabled:RouteDisplay FC <fl>
If
FCMultiNode
is enabled: RouteDisplay FC <fp> <fl>
SASTargets
Lists the physical devices that are connected to all SAS ports.
SASTargets
SaveConfiguration
Issued with the
restart
option, cycles unit power after saving
configuration changes. The
norestart
option saves changes
without restarting.
Note
Certain modifications require a system restart.
SaveConfiguration <Restart | NoRestart>
SerialNumber
Displays the serial number of the unit. The serial number is a 13
character field. The first seven alphanumeric characters are an
abbreviation representing the product name. The remaining six
digits are the individual unit’s number.
get SerialNumber
SerialPortBaudRate
Configures the baud rate for the unit’s RS-232 serial port. The
number of data bits per character is fixed at 8 with no parity.
Default: 115200
set SerialPortBaudRate [9600 | 19200 | 38400 | 57600 |
115200]
SaveConfiguration Restart command required
get SerialPortBaudRate
SerialPortEcho
Controls if the unit echoes characters on its RS-232 port. When
enabled, all non-control character keyboard input is output to
the display.
Default: enabled
set SerialPortEcho [enabled | disabled]
get SerialPortEcho
SNTP
Controls whether an SNTP time server sets the date and time.
Default: enabled
set SNTP [enabled | disabled]
SaveConfiguration Restart command required
get SNTP
SNTPServer
Controls or displays the main IP address the client uses to
retrieve the SNTP time and date.
Default: 192.43.244.18
set SNTPServer [xxx.xxx.xxx.xxx]
SaveConfiguration Restart command required
get SNTPServer
TailEventLog
Displays new events to the terminal. Type
quit t
hen press
ENTER t
o exit tail mode.
TailEventLog
Temperature
Displays the current internal operating temperature of this unit
in degrees Celsius.
get Temperature
Time
Controls or displays the current time as clocked by the unit in 24
hour format.
set Time [HH: MM: SS]
get Time
TimeZone
Controls or displays the time zone or an offset from GMT for the
unit.
Default: EST
set TimeZone [[EST | CST | MST | PST] | [+/-HH:MM]]
SaveConfiguration command required
get TimeZone
Username
Specifies the user name.
Username
is case insensitive, 1 to
32 characters, and cannot contain spaces.
Default: root
set Username [username]
SaveConfiguration command required
get Username
VerboseMode
Controls the level of detail in CLI
Help
output and command
response output for the current CLI session.
Default: enabled
set VerboseMode [enabled | disabled]
get VerboseMode