Specifications

xii
RGHaltConversion
Stops the conversion of the specified RAID group.
RGHaltConversion [group name]
RGHaltErase
Stops the erase on the specified RAID group.
RGHaltErase [group name]
RGHaltRebuild
Stops the rebuild(s) on the specified RAID group. If no member
index is specified, all rebuilds on that RAID group are stopped.
RGHaltRebuild [group name] <member index>
RGMemberAdd
Adds available block devices to a new RAID group (before
RGCommit
has been used). Up to 10 block IDs may be
specified. If
ALL
is specified, then all available unused block
IDs are added to the RAID group until the maximum number of
RAID group members has been met. The command resets the
number of RAID group partitions to 1.
RGMemberAdd [group name] [all | BlockDevID]
RGMemberRemove
Removes a RAID Member from a new RAID group (before
RGCommit
has been used). The command resets the number
of partitions to 1.
RGMemberRemove [group name] [member index]
RGRebuild
Rebuilds the specified RAID group. If no member is specified,
all degraded members are rebuilt. Optional parameter
BlockDeviceID
allows an available block device to be
substituted for the RAID member currently assigned to the
member index.
RGRebuild [group name] <member index>
<BlockDeviceID>
RGResumeConversion
Continues the stopped conversion on the specified RAID group.
RGResumeConversion [group name]
RGResumeErase
Continues the erase on the specified RAID group.
RGResumeErase [group name]
RGResumeRebuild
Continues the rebuild(s) on the specified RAID group. If no
member index is specified, all stopped rebuilds on that RAID
group are resumed.
RGResumeRebuild [group name] <member index>
RGSpanDepth
Regulates the span depth on the specified RAID group. The
RAID group must be of type RAID 0, 1, 4, 5 or 1+0.
set RGSpanDepth [group name] [SpanDepth [1-32]]
RGSpeedRead
Performs look-ahead during reads from RAID group
member disks for all or the specified RAID group.
Default: auto
set RGSpeedRead [group name | all] [enabled | disabled
| auto]
get RGSpeedRead [group name | all]
RGUnmap
Removes all mapped partitions for a RAID group from
the routing table. The partitions themselves are
unaffected, although they are inaccessible to initiators.
RGUnmap [group name | all]
RGWaitTimeout
Specifies the maximum time in seconds that the system waits to
discover previously-configured RAID groups attached to the
unit. The time out is used during system boot time and when the
BlockDevScan
command is issued.
Default: 5
set RGWaitTimeout [1-3600]
SaveConfiguration Restart command required
get RGWaitTimeout
RMStatus
Displays the status of all RAID members within the specified
RAID group or a particular RAID member if specified within the
specified RAID group.
RMStatus [group name] <member index>
Route
Assigns a host protocol address to a target destination device.
More than one FC LUN may be assigned to a partition. If you try
to map a new partition to the same FC LUN, the previous map
is overwritten. Use the
delete
identifier to remove the map. In
verbose mode, overwriting a map requires secondary
confirmation of the action.
If
FCMultiNode
is disabled: Route FC [fl] [[RAID [Group
Name] [Partidx]] | Bridge | Delete]
If
FCMultiNode
is enabled: Route FC [fp] [fl] [RAID
[Group Name] [Partidx]] | Bridge | Delete]