Specifications
xii
RGHaltConversion 
Stops the conversion of the specified RAID group.
RGHaltConversion [group name]
RGHaltErase
Stops the erase on the specified RAID group.
RGHaltErase [group name]
RGHaltRebuild
Stops the rebuild(s) on the specified RAID group. If no member 
index is specified, all rebuilds on that RAID group are stopped.
RGHaltRebuild [group name] <member index>
RGMemberAdd
Adds available block devices to a new RAID group (before 
RGCommit
 has been used). Up to 10 block IDs may be 
specified. If 
ALL
 is specified, then all available unused block 
IDs are added to the RAID group until the maximum number of 
RAID group members has been met. The command resets the 
number of RAID group partitions to 1.
RGMemberAdd [group name] [all | BlockDevID]
RGMemberRemove 
Removes a RAID Member from a new RAID group (before 
RGCommit
 has been used). The command resets the number 
of partitions to 1.
RGMemberRemove [group name] [member index]
RGRebuild
Rebuilds the specified RAID group. If no member is specified, 
all degraded members are rebuilt. Optional parameter 
BlockDeviceID
 allows an available block device to be 
substituted for the RAID member currently assigned to the 
member index. 
RGRebuild [group name] <member index> 
<BlockDeviceID>
RGResumeConversion
Continues the stopped conversion on the specified RAID group.
RGResumeConversion [group name]
RGResumeErase
Continues the erase on the specified RAID group.
RGResumeErase [group name]
RGResumeRebuild
Continues the rebuild(s) on the specified RAID group. If no 
member index is specified, all stopped rebuilds on that RAID 
group are resumed.
RGResumeRebuild [group name] <member index>
RGSpanDepth
Regulates the span depth on the specified RAID group. The 
RAID group must be of type RAID 0, 1, 4, 5 or 1+0.
set RGSpanDepth [group name] [SpanDepth [1-32]]
RGSpeedRead
Performs look-ahead during reads from RAID group 
member disks for all or the specified RAID group. 
Default: auto
set RGSpeedRead [group name | all] [enabled | disabled 
| auto]
get RGSpeedRead [group name | all]
RGUnmap
Removes all mapped partitions for a RAID group from 
the routing table. The partitions themselves are 
unaffected, although they are inaccessible to initiators. 
RGUnmap [group name | all]
RGWaitTimeout
Specifies the maximum time in seconds that the system waits to 
discover previously-configured RAID groups attached to the 
unit. The time out is used during system boot time and when the 
BlockDevScan
 command is issued.
Default: 5
set RGWaitTimeout [1-3600]
SaveConfiguration Restart command required
get RGWaitTimeout
RMStatus
Displays the status of all RAID members within the specified 
RAID group or a particular RAID member if specified within the 
specified RAID group. 
RMStatus [group name] <member index>
Route 
Assigns a host protocol address to a target destination device. 
More than one FC LUN may be assigned to a partition. If you try 
to map a new partition to the same FC LUN, the previous map 
is overwritten. Use the 
delete
 identifier to remove the map. In 
verbose mode, overwriting a map requires secondary 
confirmation of the action.
If 
FCMultiNode
 is disabled: Route FC [fl] [[RAID [Group 
Name] [Partidx]] | Bridge | Delete]
If 
FCMultiNode
 is enabled: Route FC [fp] [fl] [RAID 
[Group Name] [Partidx]] | Bridge | Delete]










