Specifications

x
MaxOpTemp
Regulates the maximum operating temperature of this unit in
degrees Celsius. Valid entries are between 55 and 70 degrees.
Default: 70
set MaxOpTemp [55 – 70]
SaveConfiguration Restart command required
get MaxOpTemp
Metrics
Controls the collection of standard data metrics within a product.
Metrics [Start | Stop | Display | Clear] [[drive [BlockDevID]
| all | running]
MinOpTemp
Regulates the minimum operating temperature of this unit in
degrees Celsius. Valid entries are between 0 and 15 degrees.
Default: 0
set MinOpTemp [0 – 15]
SaveConfiguration Restart command required
get MinOpTemp
OpTempWarn
Regulates the number of degrees Celsius before a thermal
control event precipitates a warning to the user. Valid entries are
between 0 and 15 degrees.
Default: 5
set OpTempWarn [0 – 15]
SaveConfiguration Restart command required
get OpTempWarn
Partition
Sets the specified partition to the specified capacity in gigabytes
(GB), megabytes (MB), or blocks. The specified capacity must
be smaller than the specified partition’s current capacity. A new
partition is created to acquire the remainder of the original
partition’s space.
VirtualDriveInfo
displays characteristics and
statistics for all the available virtual drives or any available
virtual drive identified by its virtual drive ID.
Partition [group name] [partition index] [capacity] [GB |
MB | blocks]
PartitionDisplay
Lists all the partitions available in the specified RAID group. The
partitions are listed in order of contiguousness (as opposed to
index order).
PartitionDisplay [group name]
PartitionMerge
Combines the specified contiguous partitions into one partition.
Partition index
is the index of a partition to merge, along with
a number of contiguous partitions to merge to that index.
All
indicates that all partitions in the RAID group are merged into a
single Virtual Disk. The RAID group must not be in a NEW state.
None of the partitions to merge may be mapped.
PartitionMerge [group name] [[[partition index] [2-128]] |
all]
PartitionSplit
Divides the specified partition into one or more partitions whose
capacities are evenly distributed among the capacity of the
original partition. The partition to split cannot be mapped. The
RAID group must not be in a NEW state.
PartitionSplit [group name] [partition index] [2-128]
Password
Specifies the password used for all sessions. Password is case
sensitive, 0 to 32 characters, and cannot contain spaces. An
empty password can be configured by pressing the enter key
when prompted for the new password and new password
confirmation.
Default: Password
set Password
Performance
Lists the performance data for the user-specified Fibre Channel
port. Data consists of the average rate (MB/sec) and number of
I/Os (IO/sec) measured over the previous sampling period
(approximately one second). Successful Read and Write
commands are considered I/Os. Factors that may affect
reported performance include port availability and saturation
and overall system utilization.
get Performance <fp>
Ping
Sends an ICMP echo request to the specified host.
ping [mp1] [xxx.xxx.xxx.xxx] <count <size>>
RAIDRebuildPriority
Regulates or displays the RAID rebuild priority. A RAID rebuild
priority set to
high
gives higher priority to RAID rebuilds and
lower priority to the processing of simultaneous I/O
transactions. A RAID rebuild priority set to
low
gives lower
priority to the rebuild and a higher priority to I/O transactions.
Set
same
, the RAID rebuild and processing of I/O transactions
is the same.
Default: same
set RAIDRebuildPriority <GroupName | all> [high | low |
same]
SaveConfiguration command required
get RAIDRebuildPriority <GroupName | all>