Specifications
v
ATTO Technology Inc. FastStream SC Installation and Operation Manual
CLI command explanations
Command Line Interface commands are listed alphabetically with explanations of what they are used for, their 
defaults and syntax.
CAUTIONCAUTION
Using CLI without contacting an ATTO 
technician is not recommended because 
changing parameters may cause loss of 
data and/or disruption to performance and 
reliability of the FastStream. 
The ExpressNAV Storage Manager is the 
preferred method to manage the 
FastStream. Refer to 
Interface Options
 on 
page 27 for details.
AutoMap 
Automatically assigns a subset of source protocol LUNs to a 
subset of target destination devices visible to the unit. The unit 
reports a five-second delay while it scans for devices. All 
previous maps are deleted.
If 
FCMultiNode
 is enabled (multiple node): 
AutoMap <fp>
SaveConfiguration command required
If 
FCMultiNode
 is disabled (single node): AutoMap
SaveConfiguration command required
AutoResume
Regulates the 
AutoResume
 features for interrupted rebuild 
and erase operations at startup. If no group name is specified, 
all existing RAID groups are affected.
Default: enabled for AutoResume Rebuild
disabled for AutoResumeErase
set AutoResume [Rebuild | Erase | All ] [enabled | 
disabled] <group name>
BlockDevClean 
Removes any RAID configuration data from the block device 
with the specified block ID. 
CAUTIONCAUTION
All RAID group setup information is lost 
and you lose all RAID group data.
BlockDevClean [BlockDevID]
BlockDevIdentify 
Lights the LED of a disk drive. Use either RAID group name and 
member index, or block ID. 
BlockDevIdentify <Group name> [BlockDevID | member 
index]
SaveConfiguration saveconfiguration restart
SerialNumber get serialnumber
SerialPortBaudRate 115200 set serialportbaudrate 19200
SerialPortEcho enabled get serialportecho
SNTP enabled get sntp
SNTPServer 192.43.244.18 set sntpserver 129.6.15.28
TailEventLog taileventlog
Temperature get temperature
Time set time 03:32:30
TimeZone EST set timezone pst
Username root set username Barbara
VerboseMode enabled set verbosemode disabled
VirtualDriveInfo virtualdriveinfo
Voltage get voltage
WrapEventLog enabled set wrapeventlog disabled
zModem zmodem receive
Command Default Example