Instruction manual
xv
ATTO Technology Inc. FastStream SC 5700 Installation and Operation Manual
RGWaitTimeout
Specifies the maximum time in seconds that the system
waits to discover previously-configured RAID groups
attached to the FastStream. The timeout is used during
system boot time and when the
BlockDevScan
command is issued.
Default: 5
set RGWaitTimeout [1-3600]
get RGWaitTimeout
RGWritePattern
Writes a DWORD pattern of four hexadecimal bytes to
the entire specified existing RAID Group.
WARNING
If you use the RGWritePattern command,
the RAID Group is set to offline and all data
is lost.
RGWritePattern [GroupName] [Pattern]
RMState
Sets the member state on the specified existing RAID
group member(s). RAID group may not be in the NEW
state. Optional parameter MemberIndex specifies the
RAID Member whose status is to be set. If no
MemberIndex is specified, the status of all members of the
specified RAID group is set.
Note
Members undergoing rebuild are not changed.
Rebuilds on these members must first be
stopped.
set RMState [GroupName] <MemberIndex> [Online |
Degraded | Unavailable | Faulted]
RMStatus
Displays the status of all RAID Members within the
specified RAID group or a specific RAID member (if
specified) within the specified RAID group. This
command fails if the specified RAID group does not exist
or a specified member index within the RAID group does
not exist.
RMStatus [GroupName] <MemberIndex>
Route
Assigns a host protocol address to a target destination
device. More than one FC LUN may be assigned to a
partition. If you try to map a new partition to the same
FCLUN, the previous map is overwritten. Use the delete
identifier to remove the map. In verbose mode, secondary
confirmation must be made.
FCMultiNode
disabled: Route FC [fl] [ RAID
[GroupName] [PartIndex] ] | Bridge | Delete ]
FCMultiNode
enabled: Route FC [fp] [fl] [ RAID
[GroupName] [PartIndex] ] | Bridge | Delete ]
RouteDisplay
Displays a list of Fibre Channel to address mappings on
the FastStream.
FCMultiNode
disabled: RouteDisplay FC <fl>
FCMultiNode
enabled: RouteDisplay FC <fp> <fl>
SaveConfiguration
Issued with the restart option, cycles unit power after
saving configuration changes. The
norestart
option
saves changes without restarting.
Note
Certain modifications require a system restart.
SaveConfiguration <Restart | NoRestart>
SerialNumber
Reports the FastStream serial number which is unique for
each FastStream. The serial number tracks the board
throughout its life and should not be changed.
get SerialNumber
SerialPortBaudRate
Configures the baud rate for the unit’s RS-232 serial port.
The number of data bits is fixed at
8
with no parity.
set SerialPortBaudRate [ 2400 | 9600 | 19200 | 38400 |
57600 | 115200]
get SerialPortBaudRate
SerialPortEcho
Controls if the unit echoes characters on its RS-232 port.
When enabled, all non-control character keyboard input
is output to the display.
Default: enabled
set SerialPortEcho [enabled | disabled]
get SerialPortEcho