ATTO Technology Inc. FastStream SC 5700 Installation and Operation Manual
Help
Displays a list of available commands. If command name
is specified, displays detailed command-specific
information.
Help <command name>
HSAdd
Assigns a Block Device to the Hot Spare pool.
HSAdd [BlockDevID]
HSDisplay
Lists all devices in the Hot Spare pool.
HSDisplay
HSRemove
Removes a Block Device from the Hot Spare pool
HSRemove [BlockDevID]
IdentifyBridge
Enabling this option causes the front panel Ready LED of
the FastStream to blink until the parameter is disabled.
Default: disabled
set IdentifyBridge [enabled | disabled]
get IdentifyBridge
Info
Displays version numbers and other production
information for key components.
Info
IPAddress
Regulates the current FastStream IP address.If IPDHCP
is enabled (see below), get command reports current IP
address assigned by DHCP server. Setting this value
always modifies the internal NVRAM value of the IP
Address, whether or not a
SaveConfiguration
is
performed.
set IPAddress [mp1] xxx.xxx.xxx.xxx
get IPAddress [mp1]
IPDHCP
Selecting DHCP allows the FastStream to request an IP
address from the network. The network must have at least
one DHCP server.
Default: enabled
set IPDHCP [mp1] [enabled | disabled]
Requires a SaveConfiguration command
get IPDHCP [mp1]
IPGateway
Controls the current default gateways used by any
Ethernet port(s) on the unit. If
IPDHCP
is enabled, the
‘get’ command reports the current IP gateway assigned
by the network DHCP server.
set IPGateway [mp1] [xxx.xxx.xxx.xxx]
get IPGateway [mp1]
IPSubnetMask
Sets/displays the current subnet mask. If
IPDHCP
is
enabled (see above), get command reports current subnet
mask assigned by DHCP server. Setting this value always
modifies the internal NVRAM value of the IP subnet mask
whether or not a
SaveConfiguration
is performed.
set IPSubnetMask xxx.xxx.xxx.xxx
get IPSubnetMask
IsReserved
Displays the reservation status of the current unit.
IsReserved
MaxOpTemp
Regulates the maximum operating temperature of this
unit in degrees Celsius. Valid entries are between 55 and
70 degrees.
Default: 70
set MaxOpTemp [55 – 70]
get MaxOpTemp
Metrics
Controls the collection of standard data metrics within a
product via the command’s Start, Stop and Display
parameters.
Metrics [Start | Stop | Display] [drive [BlockDevID] | all |
running]
MinOpTemp
Regulates the minimum operating temperature of this unit
in degrees Celsius. Valid entries are between 0 and 15
degrees.
Default: 0
set MinOpTemp [0 – 15]
get MinOpTemp
OpTempWarn
Regulates the number of degrees Celsius before a thermal
control event precipitates a warning to the user. Valid
entries are between 0 and 15 degrees.
Default: 0
set OpTempWarn [0 – 15]
get OpTempWarn