ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual
SCSIPortList
Lists the status of all available SCSI ports.
SCSIPortList
SCSIPortReset
Resets the specified SCSI bus.
SCSIPortReset [sb]
SCSIPortResetOnStartup
Controls whether the specified SCSI bus is reset each
time the unit is powered up.
set SCSIPortResetOnStartup [sb] [enabled | disabled]
get SCSIPortResetOnStartup [sb]
SCSIPortSelTimeout
Controls the time in milliseconds that the unit waits for a
response from a device on the specified SCSI port after a
selection request.
CAUTIONCAUTION
If you set this value too low, failures may
occur during normal operation.
Default: 250
set SCSIPortSelTimeout [sb] [ 250 | 128 | 64 | 32 | 16 | 8
| 4 | 2 | 1 ]
get SCSIPortSelTimeout [sb]
SCSIPortSyncTransfer
Controls the unit’s attempts to negotiate synchronous
SCSI transfers with devices on the specified bus.
Default: enabled
set SCSIPortSyncTransfer [sb] [enabled | disabled]
get SCSIPortSyncTransfer [sb]
SCSIPortTermination
Configures the SCSI internal termination of the specified
SCSI port. Enabling termination allows the unit to act as
a terminator at the end of a SCSI chain.
Default: enabled
set SCSIPortTermination [sb] [enabled | disabled]
get SCSIPortTermination [sb]
SCSIPortWideTransfer
Controls the unit’s attempts to negotiate wide SCSI
transfers with devices on the specified bus.
Default: enabled
set SCSIPortWideTransfer [sb] [enabled | disabled]
get SCSIPortWideTransfer [sb]
SCSITargetLUNs
Controls the maximum number of SCSI LUNs per target
the unit queries during a SCSI bus scan.
set SCSITargetLUNs [sb] [8 | 64]
get SCSITargetLUNs [sb]
SCSITargets
Lists the physical devices that are connected and running
on the specified SCSI port.
SCSITargets [sb]
SerialNumber
Reports the FastStream serial number which is unique for
each FastStream. The serial number tracks the board
throughout its life and should not be changed.
get SerialNumber
SerialPortBaudRate
Configures the baud rate for the unit’s RS-232 serial port.
The number of data bits is fixed at
8
with no parity.
Default:
set SerialPortBaudRate [ 9600 | 19200 | 38400 | 57600 |
115200]
get SerialPortBaudRate
SerialPortEcho
Controls if the unit echoes characters on its RS-232 port.
When enabled, all non-control character keyboard input
is output to the display.
Default: enabled
set SerialPortEcho [enabled | disabled]
get SerialPortEcho
SNTP
Controls whether SNTP time server is used.
Default: enabled
set SNTP [enabled | disabled]
get SNTP
SNTPServer
Controls or displays the main IP address the client uses
to retrieve the SNTP time.
Default: 192.43.244.18
set SNTPServer[xxx.xxx.xxx.xxx]
get SNTPServer