Instruction manual
27
ATTO Technology Inc. FastStream SC 5300 Installation and Operation Manual
6.0 Interface options
The best way to manage, monitor and configure the FastStream SC 5300 is to use the ExpressNAV
interface, a browser-based application included with your FastStream, but you may use a terminal
emulation program or Telnet.
Use the ExpressNAV interface
Use the ExpressNAV interface, a browser-based
GUI, to manage, monitor and configure the unit.
The choices you make lead you from screen to
screen. Choices which are not available are
greyed out.
1 Working from the computer attached to the
FastStream SC 5300 Ethernet port, open your
browser and type in the FastStream SC 5300 IP
address as noted in Discover the IP address
on
page 5.
2 Your browser points to the FastStream SC
5300 splash screen. Press Enter.
3 Type in the user name and password values.
Note
The default values are user name:
root
and
password:
Password
. The user name is case
insensitive and the password is case sensitive.
It is best practice to change the user name and
password. Refer to
Change current user
name, password
on page 15.
The pages which next appear depend on whether
or not you have begun configuring the FastStream
SC 5300. Refer to
Configure RAID
on page 7.
Use the serial port
To connect to a terminal emulation program or
Telnet to manage the FastStream SC 5300, use the
serial port.
1 Connect a cable from FastStream SC 5300 RS-
232 serial port or header to the serial (COM)
port on a personal computer.
2 Turn on the FastStream SC 5300.
3 Start a terminal emulation program on the
personal computer, and use it to connect to the
FastStream SC 5300. For example, if you are
using Hyper Terminal on a computer running a
Windows operating system,
a. Type FastStream SC 5300 in the New
Connection dialog box.
b. Click OK.
c. In the Connect To dialog box in the
Connect using field, select the COM port
number to which your serial cable is
connected.
d. Click OK.
e. In the COM Properties dialog box select the
following values:
• Bits per second: 115200
• Data Bits: 8
• Parity: None
• Stop Bits: 1
• Flow Control: None
• Terminal type: ASCII
• Echo: on
f. Click OK.
4 After you connect to the FastStream SC 5300,
start-up messages are displayed. The last line
in the start-up message sequence is Ready.
Make adjustments to the FastStream SC 5300
using the Command Line Interface as described
in CLI provides an ASCII-based interface
on
page v of the Appendix.
Note
In serial port sessions, there is no prompt on
the line below the word
Ready
. Begin typing
commands in the blank line where the cursor
is resting. No user name or password is
required for serial port access.
5 To verify that you have connected successfully,
type help after the Ready prompt and press
Enter.
If a list of all available commands does not
appear on the screen, review the steps in this
section, check the cable, or contact service
personnel until the problem is solved.
If you have difficulty using the serial port, verify
that you have the correct settings and that your
serial cable is less then two meters in length.