Installation manual

vii ATTO Technology Inc. ATTO Utilities Installation and Operation Manual
BlockDevScan (Immediate, Disabled on Error)
BlockDevScan lists all currently connected physical block
devices along with any potential RAID Group association. Each
block device listed is assigned a unique index at the time of the
scan. This index is used to identify block devices for other CLI
operations.
Usage: BlockDevScan
BuzzerOnError (OEM Configurable)
(6Gb RAID
Adapter w/CacheAssure)
When enabled, the audible alarm will sound under error
conditions. When disabled, the audible alarm is muted.
Usage: set BuzzerOnError [enabled | disabled]
get BuzzerOnError
BuzzerTest (Immediate)
(6Gb RAID Adapter
w/CacheAssure)
Turns the audible alarm on or off regardless of the
BuzzerOnError state. The optional seconds parameter specifies
the length of time that the alarm is on. If the seconds parameter
is omitted, the audible alarm will not turn off until the BuzzerTest
Off command is issued.
Usage: BuzzerTest [on <seconds> | off]
CACacheStatus
(6Gb RAID Adapter
w/CacheAssure)
Returns the current status of the CacheAssure NV Memory
Card. This includes whether or not it is installed.
Usage: get CACacheStatus
CACleanCache (Immediate)
(6Gb RAID Adapter
w/CacheAssure)
Deletes the contents of CacheAssure flash memory. Warning:
CacheAssure may contain data for drives that are not
connected, and issuing this command will cause that data to be
lost!
Usage: CACleanCache
CAPowerStatus
(6Gb RAID Adapter
w/CacheAssure)
Returns the current status of the CacheAssure Power Module.
This includes whether or not it is installed and whether or not it
is fully charged.
Usage: get CAPowerStatus
CAProtectionMode (OEM Configurable, Disabled on
Error)
(6Gb RAID Adapter w/CacheAssure)
Use this command to determine behavior when CacheAssure is
installed. HiProtection mode causes Disk Write Caching to be
immediately Disabled for new and existing RAID Groups.
HiPerformance mode enables Disk Write Caching for new and
existing RAID Groups with a small risk of data loss on power
failure.
Usage: set CAProtectionMode [HiProtection |
HiPerformance]
get CAProtectionMode
ClearEventLog (Immediate)
ClearEventLog clears the contents of the event log.
Usage: ClearEventLog
Date
Sets/displays the current date. The date range is 01/01/2000 to
12/31/2099.
Usage: set Date [MM/DD/YYYY]
get Date
DeleteScheduledTasks (Immediate, Disabled on
Error)
Deletes a scheduled task with the Id returned by
DisplayScheduledTasks.
Usage: DeleteScheduledTasks [Id]
DisplayScheduledTasks (Immediate, Disabled on
Error)
Immediate command that displays all outstanding scheduled
tasks.
Usage: DisplayScheduledTasks
DriveAssureReport (Immediate, Disabled on Error)
Displays drive timeout error statistics for all member drives in
the specified RAID group.
Usage: DriveAssureReport [GroupName]
DriveHealth (OEM Configurable, Disabled on Error)
Changes the system's ability to acquire drive health data from
connected drives. Issuing this command during I/O operations
may adversely affect performance.
Usage: set DriveHealth [enabled | disabled]
get DriveHealth