Installation manual
vi
CLI command explanations
Command Line Interface commands are listed alphabetically with explanations of what they are used for, their
defaults and syntax.
CAUTIONCAUTION
Using CLI without contacting an ATTO technician is not recommended because changing
parameters may cause loss of data and/or disruption to performance and reliability of the
ExpressSAS adapter.
AutoMap (Immediate, Disabled on Error)
Automap automatically maps each RAID Partition to a Target ID
on the host system (maximum 256 maps allowed). If the
optional 'passthrough' parameter is entered then AutoMap
stores maps for currently connected SAS/SATA Pass Through
Devices. Existing maps for available targets are preserved.
Usage: AutoMap <passthrough>
AutoMapOnBoot (OEM Configurable, Disabled on
Error)
(Not valid for 3808)
Enables or disables automatic device detection and mapping
(
AutoMap (Immediate, Disabled on Error)
) at startup.
Usage: set AutoMapOnBoot [enabled | disabled]
get AutoMapOnBoot
AutoResume
AutoResume sets or gets the AutoResume features for
interrupted rebuild, write pattern, erase, initialization, media
scan, and conversion operations at startup. Optional parameter
GroupName specifies the RAID group to operate on. If no
GroupName is specified, the command operates on all existing
RAID groups.
Usage: set AutoResume [Rebuild|WritePattern
|Erase|Initialization|MediaScan|Conversion|all]
[enabled|disabled] <GroupName>
get AutoResume
[Rebuild|WritePattern|Erase|Initialization|MediaScan|
Conversion|all]
BlockDevClean (Immediate, Disabled on Error)
BlockDevClean removes any RAID configuration data from the
block device with the specified BlockDevID. BlockDevID is the
index of a block device provided by the BlockDevScan CLI
command. Caution: All RAID Group setup information is lost
and you lose all RAID Group data.
Usage: BlockDevClean [BlockDevID]
BlockDevIdentify (Immediate, Disabled on Error)
Lights the LED of a disk drive. Use either RAID Group name and
member index, or BlockDevID. BlockDevID is the index of a
block device provided by the BlockDevScan CLI command.
Usage: BlockDevIdentify [[Groupname MemberIndex] |
BlockDevID]
BlockDevIdStop (Immediate, Disabled on Error)
Turns off the IO LED of a previously identified disk drive. Specify
RAID group name and member index, BlockDevID, or no
parameters (which will turn off all previously identified drives).
BlockDevID is the index of the block device provided by the
BlockDevScan CLI command.
Usage: BlockDevIdStop <[GroupName MemberIndex] |
BlockDevID>
BlockDevInfo (Immediare, Disabled on Error)
BlockDevInfo gives detailed information about connected
physical block devices along with any potential RAID Group
association.
Usage: BlockDevInfo [BlockDevID | all]
SESPoll 30 set sespoll 0
SESStartingSlot 1
SESStatus
Temperature get temperature
Time set time 03:32:30
TimeZone EST set timezone pst
VerboseMode enabled set verbosemode disabled
VirtualDriveInfo virtualdriveinfo
Command Default Example