Technical data

Figure 8 IO Registry report
Removing the Celerity FC host adapter driver and utilities
To remove the Celerity FC host adapter driver and utilities, use the Uninstall command script in
/System/L
ibrary/Extensions/ATTOCelerityFCUtils.
Troubleshooting examples
This section describes problems and provides recommended steps for resolution. Perform the steps
in the
order presented.
Celerity FC host adapter does not appear in ASP
Problem: Th e Celerity FC host adapter is installed but is not listed in the ASP output.
To
troubl
eshoot this
problem, perform the following steps:
1. Ensure that the host adapter is seated pro perly by powering down the computer and reseating
the
host adapter.
2. Verify t
he host adapterdriverinstallation.
3. Move the host adap ter to a different slot.
4. If the problem p ersists with the host adapter, replace it with a new host adapter.
5. Ensure
that the
PCIe adapter is installed in a slot con gured as x4 or x8.
6. Remov
e
any nonessential PCI cards to determine if there is a PCI bus conict.
7. Disconnect a ll Fibre Channel devices from the host adapter and reboot the computer.
If this corre cts the problem, check the Fibre Channel cable, SFPs, or Fibre Channel target devices
as described in Fibre Channel device is faulty on page 26.
•If th
e
computer does not boot, install the host adapter in a different computer.
If the host adapter works in the new computer, update the ash on the host adapter as described
in the
ATTO Celerity 2-Gb and 4-Gb Host Adapter Installation & O p eration Ma nual, and then
move
the
host adapter back to the original computer.
8. If t
he
origina l conguration still fails, contact HP and report this as a possible interoperability issue
between the host ad apter and the computer.
Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system
conguration guide
25