Technical data
Figure 8 IO Registry report
Removing the Celerity FC host adapter driver and utilities
To remove the Celerity FC host adapter driver and utilities, use the Uninstall command script in
/System/L
ibrary/Extensions/ATTOCelerityFCUtils.
Troubleshooting examples
This section describes problems and provides recommended steps for resolution. Perform the steps
in the
order presented.
Celerity FC host adapter does not appear in ASP
Problem: Th e Celerity FC host adapter is installed but is not listed in the ASP output.
To
troubl
eshoot this
problem, perform the following steps:
1. Ensure that the host adapter is seated pro perly by powering down the computer and reseating
the
host adapter.
2. Verify t
he host adapterdriverinstallation.
3. Move the host adap ter to a different slot.
4. If the problem p ersists with the host adapter, replace it with a new host adapter.
5. Ensure
that the
PCIe adapter is installed in a slot con fi gured as x4 or x8.
6. Remov
e
any nonessential PCI cards to determine if there is a PCI bus conflict.
7. Disconnect a ll Fibre Channel devices from the host adapter and reboot the computer.
• If this corre cts the problem, check the Fibre Channel cable, SFPs, or Fibre Channel target devices
as described in “ Fibre Channel device is faulty” on page 26.
•If th
e
computer does not boot, install the host adapter in a different computer.
• If the host adapter works in the new computer, update the flash on the host adapter as described
in the
ATTO Celerity 2-Gb and 4-Gb Host Adapter Installation & O p eration Ma nual, and then
move
the
host adapter back to the original computer.
8. If t
he
origina l configuration still fails, contact HP and report this as a possible interoperability issue
between the host ad apter and the computer.
Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system
configuration guide
25