Setup guide

Version 3.3 Upgrade Notes
34
26. Click Next. It takes several minutes to install the driver. This time
varies based on the Avid workstation. When finished, the Completing
the Upgrade Device Driver Wizard shows a finished installing the
software message.
27. Click Finish.
28. Click Close in the Fibre Channel Controller Properties dialog box.
29. Reboot the client.
Upgrading the ATTO Firmware
You must make sure the Fibre Channel cables are disconnected from the
ATTO Fibre Channel adapter board before you proceed.
n
The ATTO configuration utility only supports ATTO 3300 Fibre Channel
adapter board.
To upgrade the ATTO firmware using the ATTO Configuration Utility:
1. Click the Start button, and select Programs > ExpressPCI
Configuration Tool. The Configuration tool opens.
2. From the Device Listing window, click the plus sign (+). The Hosts
Window opens.
3. Click the plus sign (+). The Localhost Window opens.
4. Click the Express PCI FC 3300 that appears under localhost.
5. Click the Flash tab that appears to the right of the Main Window.
6. Click the Browse button and on the MediaNetwork CD-ROM, navigate
to the flash bundle file (FlashBundle_232_2300).
7. Click the Update button.
n
The system will appear to hang for several seconds while the flash occurs.
8. When the flash completes, click OK and quit the Configuration Utility.
9. Reboot the Windows client for changes to take effect.
0578801A_UP.fm Page 34 Tuesday, May 6, 2003 4:47 PM