Diamond Storage Array Installation, Operations, Maintenance Manual
Table Of Contents
- Preface
- 1.0 Diamond Storage Array Product Overview
- 2.0 Diamond Storage Array Technical Overview
- 3.0 Installation Instructions
- 3.2 Physical Set Up
- 4.0 Determining Drive and Sled Designations
- 5.0 Accessing the Array
- Command Line Interface
- ATTO ExpressNAV
- In-band SCSI over Fibre Channel
- RS-232 port
- Ethernet port
- SNMP
- I/O details
- Browser compatibility
- Opening an ExpressNAV session
- Navigating ExpressNAV
- Exhibit 5.4-1 Atypical page in the ATTO ExpressNAV configuration tool.
- Status
- Ethernet
- SNMP
- Serial Port
- Fibre Channel
- Storage Management
- RAID
- Clear Data
- Logical Units
- Rebuild
- Configuration
- Advanced
- Restart
- Help
- FirmwareRestart
- Help
- RestoreConfiguration
- SaveConfiguration
- SystemSN
- VerboseMode
- EthernetSpeed
- FTPPassword
- IPAddress
- IPDHCP
- IPGateway
- IPSubnetMask
- SNMPTrapAddress
- SNMPTraps
- SNMPUpdates
- TelnetPassword
- TelnetTimeout
- TelnetUsername
- FcConnMode
- FcDataRate
- FcFairArb
- FcFrameLength
- FcFullDuplex
- FcHard
- FcHardAddress
- FcNodeName
- FcPortInfo
- FcPortList
- FcPortName
- FcWWName
- SerialPortBaudRate
- SerialPortEcho
- SerialPortHandshake
- SerialPortStopBits
- AudibleAlarm
- DiamondModel
- DiamondName
- DriveCopyStatus
- DriveInfo
- FcNodeName
- FcPortList
- FcPortName
- Help
- IdentifyDiamond
- Info
- LUNInfo
- SerialNumber
- SledFaultLED
- SMARTData
- Temperature
- VirtualDriveInfo
- FcScsiBusyStatus
- FirmwareRestart
- MaxEnclTempAlrm
- MinEnclTempAlrm
- Temperature
- Zmodem
- ATADiskState
- AutoRebuild
- ClearDiskReservedAreaData
- DriveCopy
- DriveCopyHalt
- DriveCopyResume
- DriveCopyStatus
- DriveInfo
- DriveSledPower
- DriveWipe
- IdeTransferRate
- LUNInfo
- LUNState
- QuickRAID0
- QuickRAID1
- QuickRAID5
- QuickRAID10
- RAID5ClearData
- RAID5ClearDataStatus
- RAIDInterleave
- RAIDHaltRebuild
- RAIDManualRebuild
- RAIDRebuildState
- RAIDRebuildStatus
- RAIDResumeRebuild
- RebuildPriority
- ResolveLUNConflicts
- RestoreModePages
- SledFaultLED
- VirtualDriveInfo
- 6.0 Configuring Drives
- JBOD (Just a Bunch of Disks)
- RAID Level 0
- RAID Level 1
- RAID Level 10
- RAID Level 5
- Interleave
- Hot Spare sleds
- Enhancing performance
- Sled-based versus disk-based
- Exhibit 6.2-1 Sled-based QuickRAID0 stripe groups with LUN designations in a fully populated Array set up as QuickRAID0 6 sled. If sled 6 were to be withdrawn from the array, LUN 3 (grayed boxes) would be unavailable.
- Exhibit 6.2-2 Drive-based QuickRAID0 stripe groups with LUN designations in a fully populated Array set up as QuickRAID0 6 Drive. If sled 6 were to be withdrawn from the array, LUNs 2 and 5 would be unavailable.
- Exhibit 6.2-3 Configurations of a fully populated Diamond Storage Array in RAID Level 0.
- Exhibit 6.3-1 Drive sleds, LUNs and mirror partners in a RAID Level 1 configuration.
- Hot Spare sleds
- Configuring a fully-populated array
- Configuring a partially-populated array
- Removing RAID groups
- Hot Spare sleds
- 7.0 Hardware Maintenance
- 8.0 Copying Drives
- 9.0 Updating Firmware
- 10.0 System Monitoring and Reporting
- RS-232 monitoring port and CLI
- Ethernet monitoring port and CLI
- Power On Self Test (POST)
- Ready LED
- Audible alarm
- Thermal monitoring
- Power supply monitoring
- System fault LED and error codes
- Disk drive activity and disk fault LEDs
- Windows 2000 special instructions
- Error messages
- Specific situations and suggestions
- Default
- Factory Default
- Appendix A ATA Disk Technology
- Appendix B Information Commands Results
- Appendix C Product Safety
- Appendix D Specifications
- Appendix E Warranty

65
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
6.6 Rebuilding RAID Configurations
If a sled must be removed and a new sled inserted into the Diamond Storage Array while it is configured
in a RAID Level 1, 5 or 10, you must rebuild the RAID Level using CLI commands or the ExpressNAV
interface.
CAUTIONCAUTION
Selecting RAID parameters causes all
previous drive data on the Diamond
Storage Array to be erased. Make sure all of
your information is backed up before
setting up RAID groups.
When you initially set up RAID groups using the
QuickRAID
command, groups are synchronized
automatically because there is no pre-existing
data on the drives. However, drives may display
as “degraded, and you need to set all LUNs to OK
status.
The simplest method to check RAID group status
is to access the
RAID
page of the ExpressNAV
interface. Refer to
ATTO ExpressNAV: Browser-based
Interface
on page 25
.
Note
Because the ExpressNAV pages take you
through this process easily, the following
instructions are based on the CLI commands.
Use these instructions as a guide in
ExpressNAV.
To reset LUN status
1 Display the status of the array by typing
RAIDRebuildStatus
.
2 Set the sleds which are listed as degraded to a
rebuild state of OK by entering
set RAIDRebuildState [sled number] OK
To synchronize mirrored drives automatically
If mirrored drives are removed for more than 15
to 30 seconds and then re-inserted or replaced, the
replaced drives are labeled “degraded” when you
check the Array’s status by typing
RAIDRebuildStatus
. If you enable
AutoRebuild.
the
array rebuilds the degraded drives automatically
when a new drive is inserted.
Note
Drive rebuilding reduces performance. You
may want to leave
AutoRebuild
at the default
disabled
and manually rebuild during off-peak
hours, or use the
RebuildPriority
command
described below.
1 Connect to Diamond Storage Array services via
the RS-232 port or the optional Ethernet
management services card (refer to
Accessing
the Array
on page 17). You should now be in
CLI.
2 Continue with the CLI or access the RAID page
of the ExpressNAV interface (refer to
ATTO
ExpressNAV: Browser-based Interface
on page 25).
3Type AutoRebuild enabled.
4 Information displays on the screen while the
array updates NVRAM ending with a Ready*
.
5Type SaveConfiguration.
6Type
FirmwareRestart to reboot the array.
7 Reboot the host computer connected via Fibre
Channel or SCSI to the array.
8 To verify the configuration, type
RAIDRebuildStatus
9 If a rebuild is necessary, the array will
automatically rebuild drives.
Rebuild priority
Drive rebuilding reduces performance. Use the
RebuildPriority
command through the CLI or on the
RAID
page of the ExpressNAV interface to
customize when your rebuilds will occur.
Choices are
High, Low
and
Same
.
• If you select High priority, rebuild I/O requests
are implemented before system I/O requests.
• If you select Low priority, rebuild I/O requests
execute only when there are no pending I/O
requests.
• If you select Same priority, rebuild I/O and
system I/O receive equal consideration.