Specifications

3
ATTO FibreCenter 3400
Ins
tallation and Operation Manual
2 ATTO FibreCenter 3400R/D characteristics
The ATTO FibreCenter 3400R/D is a 2-Gigabit Fibre Channel hub configured with eight (8) Fibre
Channel ports and an ethernet management port. The FibreCenter 3400R/D is designed to integrate
industry leading performance and Storage Area Network (SAN) capabilities into mid-range applications
by providing a high-speed, central connection point for Fibre Channel connections.
The FibreCenter 3400R/D is a flexible hub
capable of distributing pairs of ports among 1
through 4 zones (to a total of 8 ports). Up to 48
zone configurations are possible. Zones allow
different devices to communicate more effectively
within the zone. Each zone may run at a different
speed (1 Gb or 2 Gb). Configuration is managed
through a 10BaseT Ethernet port.
The FibreCenter 3400R hub may be used in an
ATTO Fibre Channel Rack System while the
FibreCenter 3400D may be used on a desktop or
mounted in a rack.
Specifications
Eight 2-Gigabit Fibre Channel ports with
Small Formfactor Pluggable (SFP) interface
400 MB/sec. maximum throughput in full
duplex mode per zone
Auto negotiation between 2-Gigabit and 1-
Gigabit modes
Port management interface for “on-the-fly”
configuration
Ethernet configuration, management and
monitoring
Modular design for maximum data reliability,
availability and serviceability.
Support for Fibre Channel Class 2, Class 3
and Intermix specifications
Support for full-duplex data transfers
Full Fibre Channel support for FC-P2, PLDA
and public loop login
32 MB of SDRAM memory for code
execution and Ethernet packets.
4 MB of flash memory, field upgradable
through Ethernet, for code and parameter
storage.
Command Line Interface provides local and
remote management and diagnostic support
using Telnet over Ethernet
Field upgradeable firmware using FTP
through the Ethernet port
Digital retiming circuits eliminate jitter
transfer to downstream devices.
Lockable port status
Offline = Port is disconnected from FC network.
Online = Port is connected to FC network
subject to automatic bypass criteria.
Automatic bypass may be disabled to allow
link to always remain connected.
Link transmitter may be optionally disabled
when port is disabled.
Reduced power consumption.
No external monitoring of FC activity.
All settings are persistent.
ATTO FibreCenter 3400R
The ATTO FibreCenter 3400R hub provides
maximum dependable performance for high
availability systems through a hot-swappable,
dual power module when housed in one module
bay of a dual module, 1U high, industry standard
rack enclosure complete with mounting brackets.
Using two modules in the ATTO Fibre Channel