Specifications

21
ATTO FibreCenter 3400
Ins
tallation and Operation Manual
4.4 Diagnostic commands
The commands in this section only provide information about the ATTO FibreCenter 3400R/D. Access
this information using these command line interface commands in a telnet session over the Ethernet
port.
Status
Displays the status of the power supplies and the cooling fans.
Limits:
PP = power supply status; OK = operating, NG=inoperable, NI = missing
FF = cooling fan status: OK = operating
K = L
Action:
none
Information:
get Status
Return syntax: Status PS1:PP FAN1:FF PS2: PP FAN2:FF KEY:K
Return example: Status PS1:OK FAN1:OK PS2:OK FAN2:OK KEY:L
Verify Zone
Verifies the current settings against the actual hardware values. Differences are reported in the format of the Zone Info command, with the current
information on the left of the display and the hardware information on the right. If everything matches, the display will state
all ports successfully
verified.
If differences are detected, set the new values and perform a
Commit Zone
command.
Actions:
none
Information:
Verify Zone
Version
Displays the firmware version of the rack. The FibreCenter 3400R/D has two processors. Returns reflect status of the ARM firmware and the
Xilinx firmware.
Limits: n = ARM firmware version; x = Xilinx firmware version
Action: none Information:
get Version
Return: n.nn-xxx
Zone Info
Displays a formatted report of the zonelist and ports
Actions:
none
Information:
get Zone Info