Setup guide
Site Planning
17
• Provides adequate space in front of and behind the workstation components, so that you
can connect cables and service your workstation. This also provides adequate airflow
for cooling.
• A minimum clearance of 3 inches (7.6 cm) for the side and back panels of the deskside
base unit
• A table (or other surface) that is at least 60 inches wide by 48 inches deep (150 cm ×
120 cm) for the editing workstation
Electrical Requirements
Your site should meet the following electrical requirements:
• Adequate power for each workstation component, so that extension cords are not
needed.
• At least two 15-amp circuits available: one for the workstation, Nitris DNA, and
accessories and one for the Avid MediaDock LVD storage system.
• Site is away from major electrical equipment, such as motors, air conditioners, or
elevators.
• Site is not subject to static electrical buildup.
• Uses an uninterruptible power supply (UPS) to protect your workstation from sudden
power surges or losses, and to save you from the resulting loss of work.
n
Plug only your Avid DS Nitris equipment into the power strip. Do not plug in coffee makers,
radios, lights, or other such devices.
The following table describes the electrical specifications for the Avid DS system.
Electrical Specifications
Component Voltage Frequency
HP Workstation xw9300 100 to 240 V ac auto-ranging 50 to 60 Hz
Monitors 100 to 250 V ac 50 to 60 Hz
Avid Nitris DNA 100 to 240 V ac 50 to 60 Hz
Avid MediaDock LVD and
Avid MediaDock Ultra320 storage systems
90 to 264 V ac 50 to 60 Hz
Avid VideoRAID 90 to 230 V ac 50 to 60 Hz
Avid Unity ISIS media network 90 to 240 V ac 50 to 60 Hz